Loading The Tool - Central Pneumatic 68021 Set Up And Operating Instructions Manual

2” 18 gauge brad nailer
Table of Contents

Advertisement

held, carefully lift the tool and press
it against the workpiece again. The
tool must not cycle (fire). If it fails to
perform in the manner explained in bold,
have it repaired by a qualified service
technician.

Loading the Tool

FROM ACCIDENTAL OPERATION,
BEFORE LOADING:
• Wear ANSI‑approved safety
goggles with side shields. Other
people in the work area must also
wear ANSI-approved impact safety
goggles with side shields.
• Release the Trigger.
• Detach the air supply.
• Attempt to fire the Tool into a
piece of scrap wood to ensure
that it is incapable of firing any
fasteners.
1.
Depress the Latch (58) and pull back the
Sliding Magazine (52) completely.
2.
Load the pointed end of the nail strip into
the bottom of the Fixed Magazine (50),
laying the the strip flat on the bed of
Magazine.
3.
Slide strip forward into Drive Guide (40).
4.
Gently push the Sliding Magazine inward
and push forward until the Latch snaps
and locks securely. WARNING! Do not
pinch your hand.
5.
NOTE: The small window at the front
of the Sliding Magazine indicates the
amount of remaining fasteners, with
the zero ("0") marker indicating 15
pieces and 5-piece marker increments
thereafter.
Page 12
TO PREVENT
SERIOUS INJURY
For technical questions, please call 1‑800‑444‑3353.
General Operating Instructions
1.
Test the Tool, as directed in the prior
section, before each use.
2.
If automatic oiler is not used, add a few
drops of Pneumatic Tool Oil to air intake
of tool before use. Add a few drops
more after each hour of continual use.
3.
Attach the Nailer to the air supply at the
Air Inlet Plug. Start your compressor
and check the pressure, making sure it is
set at the recommended 70-120 PSI.
4.
To fire, place the nose of the Naile
on the workpiece. The Nailer should
not fire if the Safety is not depressed.
Once depressed, gently and briefly
squeeze the Trigger once. Do not fire
repeatedly; nails could bounce off of
one another, damaging the work piece or
causing PERSONAL INJURY.
5.
If the tool requires more force to
accomplish the task, verify that the
tool receives sufficient, unobstructed
airflow (CFM) and pressure (PSI).
CAUTION! TO PREVENT TOOL AND
ACCESSORY FAILURE, RESULTING
IN INJURY: Do not exceed the tool's
maximum air pressure rating. If the
tool still does not have sufficient force at
maximum pressure and sufficient airflow,
a larger tool would then be required.
6.
After use, to prevent accidents:
a. Release the Trigger.
b. Detach the air supply.
c. Attempt to fire Tool into scrap wood
to ensure it is incapable of firing.
d. Release the Trigger again.
e. Clean external surfaces with clean,
dry cloth.
f. Store indoors out of children's reach.
SKU 68021

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents