GE Appliances P2B930 Owner's Manual And Installation Instructions page 46

Self-cleaning dual fuel convection ranges
Table of Contents

Advertisement

Available languages

Available languages

Installation
Instructions
r_ Connect
the Range
to the Electrical
Supply
Skip to Step 5 if the power
cord shipped
on the range
does
not match
your
wall receptacle.
Using an Existing
NEIWA 14-50R Receptacle
Plug the range power cord into a properly grounded
wall receptacle. Skip to Step 6 if the range power cord
matches the wall receptacle.
NOTE:Your range is shipped with a/#-prong plug to be used
in a NEMA!4-50R receptacle.Shouldyou choose to change
your plug, useonly a 3-wire power cord, 3-wire conduit or
/#-wireconduit. Follow the appropriate instructions below, in
Step 5, for your application.
EffectiveJanuary 1, 1996,the National ElectricalCoderequires
that new construction(not existing)utilize a 4-conductor
connectionto an electricrange.
A range cord rated at 40 amps with 125/250 minimum
volt range is required. A 50-amp range cord is not
recommended but if used, it should be marked for use with
nominal 13A"diameter connection openings. Cure should
be taken to center the cable and strain relief within the
knockout hole to keep the edge from damaging the cable.
NOTE:A/#-conductor cord is to be used when the appliance
is installed in a mobile home or when local codes do not
permit grounding through the neutraL
r-_ Replace
the Power
Cord (Optional)
Perform this step
only
if the power
cord shipped
on the range does not match your waft receptacle.
[Z]
the strain relief screws and remove the power cord.
Remove the wire cover (on the back of the range)
by removing two (2) screws using a 1/4" nut driver.
Do not discard these screws.
_z ....
___- ....................................
2 screws to
remove wire
cover
Back of range
Wire cover
g
tab
NOTE:Thereplacement power cord must be a
3-conductor or a/#-conductor UL-listedrange cord or
conduit. Cords may be provided with ring terminals on wire
and a strain reliefdevice.
@
Follow the 3-wire power cord (option 5A),
J
@
%
Remove the 3 lower power cord terminal screws from
the terminal block and the ground screw and plate.
Place the terminal screws and ground screw in safe
location for later use.
blockJ'_/!_!'!/_l _
_H
Neutralterminal
,
_o_:._
!_
Ground plate
r--_,,Wr-:-_
,_% ;_
Igroundiog
to
\ .J['k._
1o,
"}range)
screw
'
I
46
3-wire conduit (option 5B)or 4-wire conduit (option 50
sections as appropriate for your application.