Pilot Burner Adjustment - Montigo H38SVO-ST Installation & Maintenance Manual

Outdoor ventless see through residential gas fireplace
Table of Contents

Advertisement

H*38VO-ST Outdoor Gas Fireplace
Gas Control Valve
Pilot Adjustment Screw
Inlet
Pressure
Manifold Pressure
Test Connection
Figure 33. Sit Nova 820 gas valve.

Pilot Burner Adjustment

1. Locate Pilot Adjustment Screw. (See figure 33.)
2. Adjust pilot screw to provide properly sized flame as shown in
figure 34).
3. After installing or servicing, leak test with a soap solution with main
burner on. Coat pipe and tubing joints, gasket etc. with soap solution.
Bubbles indicate leaks. Tighten any areas where the bubbles appear
until the bubbling stops completely.
Figure 34. Pilot Burner.
Troubleshooting
The following is a troubleshooting chart of possible problems:
PROBLEM
Noisy Pilot Flame
Pilot won't ignite
Main burner will
not light
Page 16
Maintenance
Power
Generator
Wall Switch
CORRECTIVE aCTIOn
Locate pilot adjustement screw on
gas control valve. Flame is decreased by
turning adjustment screw clockwise.
Disconnect remote wires and try to
light pilot. If pilot now works, remote
connections are faulty. Check wiring
diagram figure 33.
1. Check wiring (see figure 33).
2. Check wall switch for proper
connection.
Troubleshooting
If your fireplace still does not operate correctly, consult your dealer or
the manufacturer.
all service and repairs should be performed by a qualified agency.
All spare parts, optional fans, and optional trim finishes are available
from your local dealer or the manufacturer.
XG0817 - 030412