Gas Control Valve
Pilot Adjsutment Screw
Inlet Pressure
Manifold Pressure
Test Connection
Pilot Burner Adjustment
1. Locate Pilot Adjustment Screw.
2. Adjust pilot screw to provide properly sized flame as shown.
3. After installing or servicing, leak test with a soap solution with main
burner on. Coat pipe and tubing joints, gasket etc. with soap solution.
Bubbles indicate leaks. Tighten any areas where the bubbles appear
until the bubbling stops completely.
Troubleshooting
The following is a troubleshooting chart of possible problems:
PROBLEM
SOLUTION
Noisy Pilot Flame
1. Locate pilot adjustment screw on gas control valve. Flame is
decreased by turning adjustment screw clockwise.
Pilot won't ignite
1. Disconnect remote wires and try to light pilot. If pilot now
works, remote connections are faulty. Check wiring diagram
figure 14.
Main burner will
1. Check wiring
not light
2. Check wall switch for proper connection.
XG0817
Power
Generator
Wall Switch
If your fireplace still does not operate correctly, consult your local
All service and repairs should be performed by a qualified
All spare parts, optional fans, and optional trim finishes are available
Installation
Montigo dealer.
Technician.
from your local Montigo dealer.
15