Section 2: Power Supply - Grizzly G0732 Owner's Manual

Contractor style saw
Table of Contents

Advertisement

SECTION 2: POWER SUPPLY

Availability
Electrocution,
equipment damage may
occur if machine is not
correctly grounded and
connected to the power
supply.
Full-Load Current Rating
Full-Load Current Rating at 110V ... 11.5 Amps
Full-Load Current Rating at 220V .... 5.7 Amps
Circuit Information
For your own safety and protection of
property, consult a qualified electrician if
fire,
or
you are unsure about wiring practices or
electrical codes in your area.
Note: The circuit requirements listed in this man-
ual apply to a dedicated circuit—where only one
machine will be running at a time. If this machine
will be connected to a shared circuit where mul-
tiple machines will be running at the same time,
consult a qualified electrician to ensure that the
circuit is properly sized for safe operation.
Circuit Requirements for 110V
Nominal Voltage ............................... 110V/120V
Cycle ..........................................................60 Hz
Phase ........................................... Single-Phase
Power Supply Circuit ......................... 15 Amps
Plug/Receptacle ............................. NEMA 5-15
Circuit Requirements for 220V
Nominal Voltage .............................. 220V/240V
Cycle ..........................................................60 Hz
Phase ........................................... Single-Phase
Power Supply Circuit ......................... 15 Amps
Plug/Receptacle ............................. NEMA 6-15
Voltage Conversion

Advertisement

Table of Contents
loading