n Attenuator
The attenuator prevents desired signals from distort-
ing when very strong signals are near the desired fre-
quency, or when very strong electric fields, such as
from broadcasting stations are near from your loca-
tion.
The attenuator can be set to both or either band sep-
arately, and the attenuation level can be set for each
band independently.
➥ Push [ATT] to turn the attenuator ON and OFF.
• "ATT" indicator appears when the attenuator is activated.
D Setting the attenuation level
q Push [M/S•BAND] or [SUB] to select the desired
band of the attenuation level to be set.
w Push [SET] then [ATT] to enter the attenuator set
mode.
e Rotate the tuning dial to select attenuation level.
• Push [M-CL 5] to return to the default value.
r Push [SET] to exit the attenuator set mode.
NOTE: When using the noise blanker, received
audio may be distorted if they are excessively
strong.
n Simple band scope
This function allows you to visually "sweep" an area
surrounding the set frequency for other signals. Detect-
ed signals are indicated graphically on the S-meter.
q Set the operating frequency and mode.
w Push [SWP 0] to turn the simple band scope func-
tion ON and OFF.
• "SWP" indicator flashes when the simple band scope
function is activated.
• Detected signals are indicated using the S-meter and
"Z" indicator, displayed above the S-meter, shows the
center frequency (displayed frequency).
• The signal availability is detected by the noise squelch
condition (open or close).
e To monitor the detected signal, rotate the tuning dial
to set the appearing "dot" of the S-meter to below
the "Z" indicator.
• The frequency readout shows the detected signal fre-
quency.
D Setting sweeping time interval
q Push [SET] then [SWP 0] to enter the sweep set
mode.
w Rotate the tuning dial to select sweeping time inter-
val.
• Push [M-CL 5] to return to the default value.
e Push [SWP 0] to exit the sweep set mode.
RECEIVE AND TRANSMIT
[ATT]
CW
ATT
Attenuation levels
144 MHz/
0–100% variable
430(440) MHz bands
Approx. 15 dB attenuation
at 100% setting
1200 MHz band
Approx. 20 dB fixed
(optional)
Shows 10 channels around the displayed
frequency.
FM
Indicates detected signals
5
VFO A
[SWP 0]
V F O A
SWP
Sweep center
29