D" Series Ceiling Cassette - Heat Controller Comfort-Cire Overview Manual

Ductless mini-split systems
Table of Contents

Advertisement

'D' Series
Ceiling Cassette Systems
Our indoor cooling only units fi t fl ush in the
ceiling with an attractive panel incorporating
airfl ow louvers. A small light display on the
indoor unit shows operation and if the timer is in
use, plus signals when the fi lter needs changing.
A full featured wireless remote and a wired wall
remote to control operation and program the unit
are both included.
To optimize comfort and minimize energy
consumption, a multi-stage compressor system in
the 36,000 BTUH unit uses two compressors that
operate individually or in tandem to closely match
the load for greatest effi ciency.
Features
n Multiple Modes for
Comfort—Cooling, fan
only, dehumidifi cation only, auto sleep modes
n Auto
Operation—Fan speed and temperature
are automatically adjusted according to the actual
temperature of the room
n Timer
Modes—Can be programmed for daily,
weekly and holiday operation for energy savings
when the room is not being used
n Swirl
Mode—Controls the louvers to reduce
temperature stratifi cation; louver swing delivers
uniform comfort
n Plasma Air Purifying
Filter—High tech fi lter
improves indoor air quality; unit also includes a
washable air fi lter
n Auto
Restart—Reverts to last programmed
setting after a power failure
n
Self-Diagnostics—Indicates when
maintenance is required
Warranty—5 years on compressor, 1 year on parts
(Some limitations apply; see printed warranty for details.)
Offi ces are ideal locations for ceiling cassettes...the overhead location
allows conditioned air to reach cubicles and work areas within a single
space. Units can be programmed on a weekly basis for comfort during
working hours and energy savings in the evenings or on weekends.
16
24 000 BTUH
24,000 BTUH
FEATURES
Power Supply
Cooling Cap. (BTUH)
SEER
Dehumidify (Pts/Hr.)
Indoor Unit
Air Flow (CFM) H/M/L
Fan Speeds (Cool/Fan)
Air Direction–Four Way
24 Hr. Timer/Sleep Mode
Defrost Control
Electrical Data Outdoor Unit*
Main Pwr. Connection
Min. Circuit Ampacity
Max. Fuse/HACR Cir Brkr.
Indoor/Outdoor Connection
Indoor Unit Chassis Dimensions
Width (inches)*
Height (inches)
Depth (inches)*
Shipping Wt (lbs)
Outdoor Unit Dimensions
Width (inches)
Height (inches)
Depth (inches)
Shipping Wt. (lbs)
C
US
* Always follow local, state and national electrical codes. Main power
connection is 208/230V.
208
208-230V/60/1
3
3 6
36,000 BTUH
000
BTUH
Cooling Only
DMC24CA-1
DMC36CA-1
208/230-1-60
208/230-1-60
23,500/24,000
33,500/34,000
13.0
13.0
6.3
7.8
650/600/550
850/800/750
3 / 3
3 / 3
Standard
Standard
Standard
Standard
Standard
Standard
Outdoor Unit
Outdoor Unit
16.8
24.3
25
40
Line Voltage
Line Voltage
Per NEC*
Per NEC*
33
33
8
8
33
33
70
70
34
35
½
31
8
12
14
175
210

Hide quick links: