Outdoor Units; Indoor Units - Heat Controller Comfort-Cire Overview Manual

Ductless mini-split systems
Table of Contents

Advertisement

TM
Mix and match indoor units up to the maximum BTUHs for each
system. The chart on the right shows the various combinations.
Note that outdoor and indoor units are ordered separately; "A"
indicates outdoor unit, "B" indicates indoor unit.
For instance, to order a 33,000 BTUH tri-zone, you'll specify one
A-VMH36QC, two B-VMH12FC, and one B-VMH09FC.

Outdoor Units

FEATURES
Power Supply
System Cooling Capacity (BTUH)
SEER
Cooling Amps
System Heating Capacity (BTUH)
Heating Amps
HSPF
OUTDOOR UNIT DIMENSIONS
Width (inches)
Height (inches)
Depth (inches)
Net Wt/Shipping Wt (lbs.)
ELECTRICAL DATA OUTDOOR UNIT*
Main Power Connection
Min. Circuit Ampacity
Max. Fuse/HACR Circuit Breaker
Recommended Indoor/Outdoor
Connecting Cable (SJOW)
LINE SETS O.D. (inch) / REFRIGERANT
Refrigerant
Liquid (flare) (inch)
Suction (flare) (inch)
Maximum Line Set Length
1
Maximum Elevation (outdoor)
2
*Always follow local, state and national electrical codes. Main power connection is 208-230V.
1 Min. 15 ft. line set recommended
2 Oil trap should be installed every 16.5 to 23 feet (5-7m).
Design, specifications and performance data subject to change without notice.
Ambient Operating Temperature: 5° - 122° F (cooling); 5° - 93.2° F (heating)
A-VMH18DC-1 A-VMH27TC-1 A-VMH36QC-1
208/230-1-60 208/230-1-60 208/230-1-60
18,000
27,000
36,000
16.0
16.0
7.5
11.0
19,000
28,000
38,000
7.6
11.2
7.7
7.7
33
1
/
33
1
/
4
4
27
3
/
27
3
/
8
8
3
3
13
/
13
/
16
16
117.9/125.7 125.7/133.4 189.6/198.4
Outdoor Unit Outdoor Unit Outdoor Unit
10.5
16.0
15
20
Line Voltage
Line Voltage
Line Voltage
per NEC*
per NEC*
per NEC*
R-410A
R-410A
R-410A
1/4
1/4
3/8
3/8
49.2 feet
49.2 feet
49.2 feet
32.8 feet
32.8 feet
32.8 feet
'V' Series InverterFlex
Multi-Zone Ductless Mini-Split HeatPumps
InverterFlex Outdoor/Indoor Combinations
OUTDOOR UNIT
A-VMH18DC-1
A-VMH27TC-1
A-VMH36QC-1
* 9K = Model No. B-VMH09FC-1, 12K = Model No. B-VMH12FC-1
15.0

Indoor Units

15.0
FEATURES
INDOOR UNIT
15.0
Cooling Capacity BTUH
8.5
Heating Capacity BTUH
Air flow (CFM)
Dehumidification (Pts/Hr)
39
Fan Speeds
37
AIR DIRECTION
13
Vertical Adjustment
Horizontal Modulating
Random Swing
INDICATOR LAMPS
ON/OFF
15.4
24 Hr. Timer/Sleep Mode
20
Defrost
Temperature Setting
INDOOR UNIT DIMENSIONS
Width (inches)
Height (inches)
1/4
Depth (inches)
3/8
Net Wt/Shipping Wt (lbs)
Liquid (flare) (inch)
Suction (flare) (inch)
Warranty—6 years on compressor, 2 year on parts
(Some limitations apply; see printed warranty for details.)
C
15
ZONES
INDOOR UNITS
TOTAL BTUH
Dual
9K + 9K
Dual
9K + 12K
Dual
12K + 12K
Tri
9K + 9K + 9K
Tri
9K + 9K + 12K
Tri
9K + 12K + 12K
Tri
12K + 12K + 12K
Quad
9K + 9K + 9K +9K
B-VMH09FC-1 B-VMH12FC-1
9,000
10,000
335/283/206
412/306/247
2.3
3
Manual
Manual
Yes
Yes
Yes
Yes
Yes
On Remote: 62° F – 88° F
31
5
/
16
10
5
/
8
6
1
/
4
22/26.5
22/26.5
1/4
1/4
*Adapter included with indoor section
US
18,000
21,000
24,000
27,000
30,000
33,000
36,000
36,000
12,000
13,000
2.5
3
Yes
Yes
Yes
Yes
Yes
33
1
/
4
11
1
/
4
6
1
/
4
3/8
1/2*