Williams 5508332 Owner's Manual page 29

Counterflow top vent gas wall furnaces
Hide thumbs Also See for 5508332:
Table of Contents

Advertisement

FOR YOUR SAFETY,
READ BEFORE
LIGHTING
WARNING:
If you do not follow these
instructions
exactly, a fire or explosion
I
may result causing
property
damage,
personal
injury or loss of life.
I
A.
This appliance
is equipped
with an ignition
device which
automatically
lights the pilot. Do not try to light the pilot
by hand.
B.
BEFORE
LIGHTING
smell around the appliance
area
for gas. Be sure to smell next to the floor
because
some
gas is heavier
than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance
or strike a match.
Do not touch any electric
switch;
do not use any
phone
in your building.
• Immediately
call your gas supplier
from a neighbor's
phone.
Follow
the gas supplier's
instructions.
C.
O.
• If you cannot
reach your gas supplier,
call the fire
department.
Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
turn by hand, don't try to repair it, call a qualified
serv-
ice technician.
Force or attempted
repair
may result in a
fire or explosion.
Do not use this appliance
if any part has been under
water.
Immediately
call a qualified
service
technician
to
inspect
the appliance
and to replace
any part of the
control system
and any gas control
which
has been
under
water.
NOTES:
FOR ADDITIONAL
INFORMATION
REFER TO THE INSTALLATION
AND OPERATION
INSTRUCTION
MANUAL
SUPPLIED
WITH THIS APPLIANCE
OR CONTACT
THE MANUFACTURER
IDENTIFYING
THE PRODUCT
BY ITS MODEL
NUMBER LOCATED
ON
THE RATING
PLATE,
FOUND
NEAR THE GAS VALVE.
LIGHTING
INSTRUCTIONS
t.
STOP! Read the safety
information
above,
2.
Set the thermostat
to lowest setting.
3.
Turn oft all electric
power to the appliance.
4.
This appliance
is equipped
with an ignition
device which
automatically
lights the pilot.
Do not try to light the pilot
by hand.
5.
Remove
control
access
panel.
6,
Turn gas control
knob clockwise(
_!_ to "OFF",
GAS
CONTROL _
KNOBSHOWN !>
F
_
.
7.
Wait five (5) minutes
to clear out any gas, then smell for
gas, including
near the floor.
It you then smell gas, stop!
Follow
"B"
in the safety
information
above.
If you don't
smell gas, go to next step,
8,
Turn the gas control
knob counterclockwise
_'
I
to "ON".
9.
Replace
control access
panel.
10.
Turn on all electric
power
to the appliance.
11.
Turn thermostat
to on (HEAT) position.
Set thermostat
higher
than room temperature.
Pilot will automatically
light and main burner(s)
will light in approximately
45
seconds.
12.
13.
14.
NOTE: On initial start-up
or after prolonged
shot down,
several ignition
cycles may be required
to purge gas
lines. To accomplish
the recycle - repeat
steps 6
through
11 until pilot is established.
Set thermostat
to desired
setting.
After the room thermostat
turns the system off, a delay
of approximately
one minute
is required
before
the
system can be turned
on again.
If the appliance
will not operate,
follow the instructions
"To Turn Off Gas To Appliance"
and call your service
technician
or gas supplier.
TO TURN OFF GAS TO APPLIANCE
1.
Set the thermostat
to lowest setting.
2.
Turn off all electric power to the appliance if service is to be performed.
3.
Remove control access panel.
4.
Push
in gas
control
knob
slightly
and
turn
clockwise
[
_, to
"OFF".
Do
not
Force.
5.
Replace
control
access
panel.
WARNING:
DUE TO HIGH SURFACE TEMPERATURES
-- KEEP CHILDREN, CLOTHING,
FURNITURE OR ANY COMBUSTIBLE
MATERIAL AWAY FROM FURNACE.
IMPORTANT:
KEEP BURNER AND CONTROL COMPARTMENT CLEAN.
--29--