Installation, cont'd
3.
Mount the MKP's faceplate to the mud ring or wall box
with machine screws (figure 2-5).
Figure 2-5 — Mounting the MKP to the wall box
4.
Reconnect the power supply and restore power.

Rear Panel and Side Panel Connections

All connectors are on the rear or side of the MKP (figure 2-6).
These connectors will be inaccessible once the MKP is installed.
1
Tx
HOST
2
Rx
RS-232
GND
LAN
Tx
SWITCH
Rx
3
RS-232
GND
12 VDC
4
GND
Figure 2-6 — MKP rear and side panels
2-8
MKP 2000 Remote Control Panel • Installation
3
U T
2
TP
O U
1
6
T
IN PU
5
R
K E
4
9
TA
8
EL
7
N C
C A
0
0
C K
0 0
B A
P 2
M K
H O
S T
R S
T x
-2 3
2
R x
L A
G N
N
S W
D
IT C
R S
H
T x
-2 3
2
R x
G N
D
1 2
V D
C
G N
D
LAN (Ethernet) port — If desired, connect a Category (CAT) 5e
1
or higher (network) cable between this connector and
either the matrix switcher to be controlled or to an
Ethernet local area network (LAN).
LAN
See TP cable termination, on page 2-12, to properly wire
the RJ-45 connector for your application.
Ethernet connection indicators — The Link and Act LEDs
indicate the status of the Ethernet connection. The Link LED
indicates that the MKP is properly connected to an Ethernet
LAN. This LED should light steadily. The Act LED indicates
transmission of data packets on the RJ-45 connector. This LED
should flicker as the MKP communicates.
Host RS-232 port — If desired, connect a host computer or
2
control system to this 3-pole, 3.5 mm, RS-232 connector
(figure 2-7).
Pin Function
Tx
HOST
Rx
RS-232
TX
Transmit data
GND
RX
Receive data
Tx
SWITCH
Rx
Gnd
Signal ground
RS-232
GND
Figure 2-7 — RS-232 connector
Switcher RS-232 port — If desired, connect a cable between this
3
3-pole, 3.5 mm, RS-232 connector and a matrix switcher
(figure 2-7).
Power connector — Plug the included external 12 VDC power
4
supply into this 2-pole captive screw connector. See Power
supply wiring, on page 2-14 to wire the connector.
MKP 2000 Remote Control Panel • Installation
2-9