3.3.11 Platen Assy
(1)
Remove the printhead (see 3.3.1).
(2)
Remove the ribbon protector (see 3.3.2).
(3)
Remove the pull-up roller Assy (see 3.3.3).
(4)
Remove the upper cover (see 3.3.1 (1) – (5)).
(5)
Turn the change lever
(6)
Push in the lock levers
by 90 .
(7)
Remove the platen Assy
(8)
To install, follow the removal steps in the reverse order.