Command
Query Firmware Version
Read controller
firmware version
Query verbose version
information
N Response description: Controller firmware version - update firmware version
Request System Status
Read system status
System Reset (Factory Default)
Absoluete System Reset
IP Setup Commands
Set matrix name
(location)
Set unit name to factory
default
24
Read matrix name
(location)
Set time/date
Read time/date
Set GMT, offset
ASCII Command
Response
(host to switcher)
(switcher to host)
X1(]
Q/q
X1(X2)X2)]
0Q
X2@]
S
E
}
ZXXX
Zpx
E
}
ZQQQ
Zpq
EX2%
}
CN
Ipn
E•
}
CN
Ipn•
E
}
X2%]
CN
EX3&
}
CT
Ipt
E
}
X2^]
CT
EX3(
}
CZ
Ipt
MPX 423 A • SIS Programming and Control
Additional description
Provide a detailed status of the
Ethernet protocol firmware, the
controller firmware, and any
firmware upgrade.
The firmware that is running is
marked by an asterisk (*).
A caret (^) indicates that the
firmware has a bad checksum
or an invalid load.
?.?? indicates the firmware is
not loaded.
]
Clears all ties, resets all audio
gains to 0 dB, and resets volume
to 100%.
]
Similar to system reset (ZXXX).
Resets IP address and subnet
mask to defaults of:
IP address = 192.168.254.254
subnet mask = 255.255.0.0
•X2%]
X2%
character max.)
Invalid characters:
+ ~ @ = ' [ ] { } < > : | \ ?
X2(]
X2(
combination of model-name
and last 3 pairs of MAC address
(e.g., MPX-423-A-00-02-3D)
X2%
character max.)
Invalid characters:
+ ~ @ = ' [ ] { } < > : | \ ?
X3&]
X3&
(MM/DDD/YY•HH:MM:SS)
X2^
[WWW,•DD•MMM•YYYY•
HH:MM:SS•GMT]
X3(]
X3(
through 14.0 hours and minutes
removed from GMT)
]
= Matrix name (24
= Default name:
= Matrix name (24
= GMT date:
= GMT date:
= GMT offset (-12.0
4-9