INSTALLATION INSTRUCTIONS
VENTING THE DRYER
WARNiNG,
[] To reduce the risk of fire, electric shock, or injury to persons
appliance, follow basic precautions,
including the following:
when using this
• Do not crush or collapse
ductwork.
Failure
to follow these instructions can result in fire
or death.
Do not allow ductwork
to rest on or
contact
sharp objects.
Failure to follow these
instructions
can result in fire or death.
• if connecting to existing
ductwork,
make
sure it is suitable
and clean before installing
the dryer. Failure to follow these instructions
can result in fire or death.
• Venting must conform to local building
codes. Failure to follow these instructions can
result in fire or death.
Gas dryers MUST exhaust
to the outdoors.
Failure to follow these instructions can result
in fire or death.
• Use only 4-inch (10.2 cm) rigid or flexible
metal ductwork
inside the dryer cabinet and
for venting outside.
Failure to follow these
instructions
can result in fire or death.
• To reduce the risk of fire, combustion,
or
accumulation
of combustible
gases, DO
NOT exhaust
dryer air into an enclosed
and
unventilated area, such as an attic, wall,
ceiling, crawl space, chimney, gas vent, or
concealed
space of a building.
Failure to
follow these instructions can result in fire
or death.
= To reduce the risk of fire, DO NOT exhaust
the dryer with plastic or thin foil ducting.
Failure to follow these instructions can result
in fire or death.
The exhaust duct must be 4 inches
(10.2 cm} in diameter
with no obstructions.
The exhaust duct should be kept as short as
possible.
Make sure to clean any old ducts
before installing your new dryer. Failure to
follow these instructions can result in fire or
death.
Rigid or semirigid
metal ducting
is
recommended
for use between the dryer
and the wall. in special installations when
it is impossible to make a connection
with
the above recommendations,
a UL=listed
flexible metal transition
duct may be used
between
the dryer and wall connection
only.
The use of this ducting will affect drying
time. Failure to follow these instructions
can
result in fire or death.
DO NOT use sheet metal screws or other
fasteners
which extend into the duct that
could catch lint and reduce the efficiency
of the exhaust
system. Secure all joints
with duct tape. Failure to follow these
instructions
can result in fire or death.
• To maximize
operating
results, please
observe the duct length limitations
noted in
the chart on page 17. Failure to follow these
instructions
can result in fire or death.
Ductwork is not provided
with the dryer.
You should obtain the necessary
ductwork
locally. The end cap should have hinged
dampers
to prevent backdraft
when the
dryer is not in use. Failure to follow these
instructions
can result in fire or death.
The Total length of flexible metal duct shall
not exceed 8 ft. (2.4m)
• in Canada, that only those foil-type
flexible
ducts, if any, specifically
identified for use
with the appliance
by the manufacturer
shall be used. In the United States, that only
those foil-type flexible ducts, if any, specifically
identified for use with the appliance by the
manufacturer and that comply with the Outline
for Clothes Dryer Transition Duct, Subject
2158A, shall be used.
16