Installation Instructions; Installation Location Requirements; Clearances - LG DLEX2550 Series Owner's Manual

Hide thumbs Also See for DLEX2550 Series:
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION INSTRUcTiONS
WARNING: Read all installation
instructions
completely
before
installing
and
operating
your
dryer!
It is important that you review this entire manual before installing and using your dryer. Detailed instructions concerning
electrical connections,
gas connections,
and exhaust requirements are provided on the following pages.
INSTALLATIONLOCATION REOUIREMENTS
[] A location that allows for proper exhaust installation.
[] A level floor with a maximum slope of 1 inch (2.5 cm)
A gas dryer must be exhausted to the outdoors. See
Venting Requirements.
[] A grounded electrical outlet located within 2 ft.
(61 cm) of either side of the dryer. See Electrical
Requirements.
[] A sturdy floor to support the total dryer weight of
200 Ibs (90.7 kg). The combined weight of a companion
appliance should also be considered.
[]
under entire dryer. If slope is greater than 1 inch (2.5
cm), install the Extended Dryer Feet Kit. Clothes may
not tumble properly, and automatic sensor cycles may
not operate correctly if dryer is not level.
For a garage installation, you will need to place the dryer
at least 18 inches (46 cm) above the floor. If using a
pedestal, you will need 18 inches (46 cm) to the bottom
of the dryer.
Do not operate your dryer at temperatures below 45 °F (7 °C). At lower temperatures,
the dryer might not shut off at the
end of an automatic cycle. This can result in longer drying times.
The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile
homes or sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the same closet as a dryer.
CLEARANCES
f 16,, mid
h"*} '_- 30"
_15"**1
(2.5 cm) (76.1cm) (12.7 cm)
_1
4-1d14"
m0x1.,_
_
H 1(35'6cm)1
'=._
_
48in. 2 .
_
(310 cm2)
_._
24 in.2. _
(155crn2)
1"'1 I_"
30" -_15"**_
(2.5 crn)
(78.1cm) (12.7crn)
(2.5cm)
11,---_11_- 27,,--_11_- 1,,
(2.5 cm)
(68.6cm)
(2.5 cm)
......
J
installation
spacing for recessed
area or closet installation
The following spacing dimensions are recommended
[] Additional spacing should be considered on all sides of
for this dryer. This dryer has been tested for spacing
of 0 inches (0 cm) clearance on the sides and rear.
Recommended
spacing should be considered for the
following reasons:
[] Additional spacing should be considered for ease of
installation and servicing.
[] Additional clearances might be required for wall, door
and floor moldings.
[]
the dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be
considered.
Suggestion:
There should be at least a little space around the dryer (or any other appliance) to eliminate the transfer
of vibration from one to the other. Too much vibration, it could cause them to make noise or touch each other causing
paint damage and making even more noise.
10

Hide quick links:

Advertisement

Table of Contents
loading