Appendix 3 "Intrusion Detection" Parameters - Panasonic AF-FX100 Setup Instructions

Image recognition box - intrusion detection
Table of Contents

Advertisement

Appendix 3 "Intrusion detection" parameters

The parameters used in the intrusion detection algorithm are shown in the table below.
Variable name
1
intrusion_disable
2
object_disable
3
th_min_size
4
th_max_size
5
th_intrusion_frame alarm threshold of intrusion
6
reserved_1
7
reserved_2
8
reserved_3
9
sensitivity
10 th_object_frame
11 flg_aspect_ratio
12 f_draw_trajectory
13 f_draw_rect_pre
14 osd_language
15 dist_mode
Message
Intrusion on: 0 off: 1
debug(syslog only): 2
Object on: 0 off: 1
debug(syslog only): 2
threshold of minimum size
threshold of maximum size
frame
Don't modify
Don't modify
Don't modify
sensitivity level
High:0 – Mid:1 - Low:6
alarm threshold of object
frame
verticaly long intruder only(1)
all intruder(0)
draw trajectory ON(1) OFF(0)
draw pre-alarm rectangle
ON(1) OFF(0)
osd language Japanese: 0
English: 1
use 3D settings (2) don't use
3D settings (0)
Description
ON/OFF flag of intrusion detection function
0: ON
1: OFF
ON/OFF flag of object abandonment/removal func-
tion
0: ON
1: OFF
Allowable range relative to standard size (human size
specified)
th_min_size (%) - th_max_size(%)
A human size is estimated with reference to the foot
position and determined by the area.
This parameter specifies the number of successive
frames to issue an alarm after detection of a human-
like object.
Setting value: 0 – 50 (frames)
Represented, for 10 fps, 0 - 5 sec.
Use the default settings.
Use the default settings.
Use the default settings.
Increase in the sensitivity enhances the detection
capability when human is not detected in the night-
time but is likely to cause excessive detection.
0: more detectable
6: less detectable
Time from object abandonment/removal to alarm
issued is specified.
Setting value: 1 - 600
Setting value x 100 (frames)
Represented, for 10 fps, 10 - 6000 sec.
Limiting only vertically oriented objects allows a false
alarm to be reduced.
0: detection of vertically and horizontally oriented
objects
1: detection of only vertically oriented objects
To display/hide the moving trajectory of an alarm tar-
get object is selected.
0: hidden
1: displayed
To display/hide a detection rectangle before determi-
nation of alarm target is selected.
0: hidden
1: displayed
The displayed language of the detection results
0: Japanese
1: English
Selection between addition of depth setting (human
size setting) and no addition is performed when
detecting an intruder.
0: no addition
1: addition
67