O. Hose
1, Remove four screws securing L.H. motor retainer,
2. Hose can be removed from motor retainer by
releasing two tabs from under side of retainer.
P. Motor
1. Remove motor retainer R.H. two screws and motor
retainer L.H. four screws.
2. Lift motor assembly upward and off of main body.
Note: When reassembling
motor to main body be careful
not to damage motor seal between motor and main body.
Q. Nozzle Height Adjustment
Cam I Cam Actuator
1. Remove bottom plate.
2, Remove valve gate.
3. Remove front wheel support.
4. Remove hood,
5. Release the two nozzle height adjustment cam
retention tabs.
The spring on the cam is replaceable.
R. Rear Wheels.
1. Release the rear wheel shaft from the main body
retention slots.
Note: The main body must be flexed on one side or the
other of the rear wheels while pulling upward on the rear
wheel shaft and then on the other side of the rear wheel
to facilitate removal.
S. Handle Release Lever
1. Remove hood.
2, Lower handle to its lowest position,
3. Release the handle lever shaft protrusion from the
main body retention slots,