Please read the operating instructions and safety precautions carefully
and thorougNy before installing and operating your room air _nditioner.
NE
MANUEL D'UTILI
C
Veuillez life attentivement et en entier ce guide d'utilisation et les
mesures de securite ci°incluses avant de proc6der & rinstallation et au
fonetionnement de votre climatiseur.
AI
ICl
E
Por favor lea las instrucciones de operaci6n y las precauciones de
seguridad cuidadosa y totalmente antes de instalar y operar su
acondicionador de aire de ventana.
MODELS,, M ODELES, MODELOS:
LXA1010ACL
LXA1030ACL

Advertisement

Table of Contents
loading

Summary of Contents for Goldstar LXA1210ACL

  • Page 1 website http:i/www.lg_rvice.com e-mail http:/iwww.lgeservice.com/techsup.Nml N ITi Please read the operating instructions and safety precautions carefully and thorougNy before installing and operating your room air _nditioner. MANUEL D'UTILI Veuillez life attentivement et en entier ce guide d'utilisation et les mesures de securite ci°incluses avant de proc6der & rinstallation et au fonetionnement de votre climatiseur.
  • Page 2: Read This Manual

    FOR "YOURRECORDS Staple your f:eceipt to this page in case you ne_ it later: Write dow¢_the mode! and serial numbers here: Model # You can find them on a label on the side of each unit, _aler's Name Date Purchased READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your air conditioner properly.
  • Page 3 fety Precautions To prevent injury to the user or other p_ple and proper%, damage, the following instructions must be followed. m Incorrect operation due to ignoring of instruction will cause harm or damage, The seriousness is classified by the following indications, This symbol indicates the possibility...
  • Page 4 •They aresharp andmay cause , Water m ay enter t heunit a nd • Since the fan rotates at higlh degra_theinsulation. It: m ay aninjury. s_ed during operation, it may cause anelectric s hock, cause an injury'. , _ not u se •This could injure thepets this air conditioner to •...
  • Page 5: Electrical Data(For 115V Model)

    Bectrical Data Electrical Data(For 115V model) Line Cord Plug Use Wall Receptacle Power Supply Parallel Use 15 AMP time delay fuse or 15 AMP circuit breaker. Standard 125V, 3-wire grounding receptacle rated 15A, 125V AC USE OF EXTENSION CORDS Because of potenti_ safety hazards, we strongly discourage the use of an extension cord. However, if you wish to use an extension cord, use a CSA certified!UL-Hsted 3-wire (grounding) extension cord, rat_ 15A, 125V.
  • Page 6 About the Controls oni the Air Conditioner The controls will look like one of the following: Controls- Coofing Only" - Turns air conditioner off. Med Fan - Med speed fan operation without cooling. Cdol Low Fan o Low speed fan operation without cooling. High Coo] -Cooling with high speed fan operation.
  • Page 7 The controls will look like one of the following: Controls- Cooling & Heating 0 ¸ ) :Turns the air conditioner off. ) : The low fan speed operation without cooling (heating). Low Cool ) : Cooling with the low speed fan operation. High Cool ( ) : Cooling with the high speed fan operation.
  • Page 8: Air-Direction Control

    Additional controls and important information. The ventilation lever is located in the right of the air discharge. The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions, When fresh air is necessary in the room, set the ventiiation lever to the OPEN position.
  • Page 9: Care And Maintenance

    Care and Maintenance TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET Air Filter Cleani j The air filter should be checked at least twice a month to see if cleaning is necessary. Trapped panicles in the filter will build up and biock the airflow This r_uces the cooling capacity and also causes an accumulation...
  • Page 10: Features And Installation

    Features and Installation Le,aming parts name prior to installation will help you understand the installation procedure. The Unit The Sleeve and the Rear Grille (optional) 11. EVAPORATOR 1, CABINET 12, CONDENSER 2, HORLZONTAL A_R DEFLECTOR (Ve_icai Louve 0 13. COMPRESSOR 3, VERTICAL AIR DEFLECTOR 14 BASE PAN...
  • Page 11: How To Install The Unit

    How to Install the Unit CAUTION ' There are sharp _ges that can cause serious cuts "_ [.,,._ CAUTION'when lifting the air cond,tbner, it is HEAVY. Use2 peoples to lift..J For existing sleeve, you should measure the wall sleeve dimensions. You _n install the new air conditioner according to these installation instructions to achieve the best performence Atl wall sleeves used to mount the new air conditioner must be in good structural condition and have the rear grille that securely attaches to the sleeve or the flange of the sleeve to...
  • Page 12: Installation Kits Contents

    Installation Kits Contents O insulation Front (1 ea) Q InsuUation Hofizon_l (2 ea) (Adhesive ..•..j j, 2,100 mm 670 mm S_eeve Assembly .p'J (optional, including expanded aluminum meta_ gdHe) (_ _nsufation V e_ica_ (4 ea) QSuF_tt Block(4 ea) @ Baffle (2 ea) Louvered Grille (Adhesivebacked) (Adhesivebacked)
  • Page 13 2 Prepare the wall sleeve for Width of the existing installation of the new unit according wail sleeve to the following installation 25-V2"(6_ ram) 2-3/_ '' (70 mm) 43/4" (120 ram) procedures. Before you prepare the wall sleeve, you should check the 253/4"...
  • Page 14 A+1/4" Remove the backing from vertical (6 mm) horizontal insulation and attach them to the inside of the wall sleeve as shown B+i/4" (6 mm) below. Wall Insulation Remove the backing from the support Horizontal blocks and attach them to the inside of the wall sleeve as shown below.
  • Page 15: Abnormal Operation

    Before you call for service ..Troubleshooting Tips Save time and money! Review the chart below first and you may not need to call for service. Normal Operation • You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high.

This manual is also suitable for:

Lxa1230aclLxa1010aclLxa1030acl

Table of Contents