Installation
Instructions
Range Hood
Questions? Ca//800.GE.CARES (800.432.2737)or V isit
our Website
at:
ge.com
I
BEFORE YOU BEGIN
Read these
instructions
completely
mid carefully,
• IMPORTANT
- S ,,e these
instructions
for local
inspector's
use.
• IMPORTANT
- Obse,,'e ;,ll
governing
codes
and ordinances.
• Note
to Installer
-
Be sure
to leave
these
instructions
with the Consumer.
• Note
to Consumer
- Keep these
instructions
for fllttlre
reference.
• Skill level - Installation
of this appliance
requires
basic mechanical
and electrical
skills.
• Completion
time - 30 minutes-3
horn's
" Proper
installation
is the responsibility
of the
installer.
• Product
taihu'e
due to improper
installation
is not
covered
trader
the Warranty.
FOR YOUR SAFETY:
WARNING
- B., e
beginning
the
installation,
switch power
off at service
panel
and
lock
the service
disconnecting
means
to prevent
power
from
being
switched
on accidentally.
When
the se_wice
disconnecting
means
cannot
be locked,
secm'elv
fasten
a prominent
warning
device,
such as a tag,
to the service
panel.
OPTIONAL
POWER CORD KIT JXHC1
An optional
Power
Cord
Connection
Kit, model
JXHC1,
is awfilable
at extra
cost from
vour GE
suI)plier
tin" installation
using
a standard
3-prong,
grounded
wall outlet.
Follow the h_stallation
Instructions
packed
with the kit to connect
the power
cord to the range
hood.
DUCTWORK
REQUIREMENTS
NOTE:
Read
the
ductwork
sections
only if you
do not
have
existing
ductwork.
If you
have
existing
ductwork,
skip
to the
"Daanage"
section
and
proceed.
The
venting
system
must
exhaust
to the
outside.
This hood
can be xented
xerticall)through
upper
cabinets
or horizontally
throtwh
an outside
wall.
Ductwork
is not included.
Exhaust connection:
The hood
exhaust
has been
designed
to mate with
standard
3¼" x 10" rectangular
ducting
or 7" diameter
round
ducting.
If a 6" round
duct is required,
a rectangulai_to-round
transition
adaptor
Inust be used*. Do not use less thm_
a 6" diaaneter
duct.
Maximum
duct length:
For satisfactory
air movement,
the total duct length
of a 3V(' x 10" rectangular,
6" or 7" diameter
rotmd
duct should
not exceed
65 equivalent
feet. See the
WORKSHEET-CALCULATE
TOTAL
EQUIVALENT
DUCTWORK
LENGTH
section.
NOTE:
It is important
that
ducting
be installed
using
the
most
direct
route
and
with
as tew
elb(m:s
as possible.
This
ensures
clear
venting
of exhaust
and
helps
prevent
blockages,
Also,
mane
sure
dampers
swing
freely
and
nothing
is blocking
the
ducts,
Elbows, transitions,
wall and roofcaps, etc.,
present
additional
resist;race
to airflow
and are
equiwdent
to a section
of straight
duct longer
than their
actual
physical
size. When
calculating
the total duct
length,
add the equiwdent
lengths
of all transitions
and
adaptors
i)lus the length
of all straight
duct sections.
The
charts
on the fl)llowing
pages
show you how to calculate
total equivalent
ductwork
length
using the approximate
feet of equivalent
length
of some
typical ducts.
* IMPORTANT:
If a rectangula>to-
rotmd
transition
adaptor
is used, the
bottom
corners
of the damper
will
haxe to be cut to fit, using the fin
snips,
in order
to allow fi'ee
moxement
of the dampeL
Equixalent
lengths
of duct pieces
are based
on actual
tests and reflect
requirements
for good xenting
performance
with any hood.