Performance Data Sheet - GE PTC22MFMALCC Owner's Manual And Installation

Profile customstyle refrigerators 22 models
Table of Contents

Advertisement

Performance Data Sheet
GE SmartWater Filtration System
GWF Cartridge
Health Claim Performance Certified by NSF/ANSI*
qOO%safety factors built in for unmetered usage)
Palameteg
USEPA
MCL
Standard No. 42: Aesthetic
Effects
Influent
Challenge
1.9 ppm
Effluent
Average
Maximum
0.02 ppm
0.05 ppm
Chlorine
T&O
.....
Particulate**
200,000
3,978
7,800
98.00%
96.10%
Parameter
'lhrKldiry
Cysts
Lead at PH 6.5
Lead at pH 8.5
Lindane
Atrazine
2,4-D
Asbestos
% Reduction
Average
Minimum
98.90%
97.37%
USEPA
MCL
1 NTU***
99.95%
Reduction
15 ppb
15 ppb
0.0002 ppm
0.003 ppm
0.100 ppm
99%
Standard
No. 53: Health
Effects
Influent
Effluent
Average
0.07 NTU
26
1 ppb
1.8 ppb
0.00005 ppm
0.002 ppm
0.042 ppm
0.32 MFL/ml
gRxiinuln
0.1 NTU
55
1 ppb
4.3 ppb
0.00005 ppm
0.003 ppm
0.090 ppm
1.2 MFL/ml
Challenge
24.3 NTU
105,750
160 ppb
150 ppb
0.00062
ppm
0.0084 ppm
0.272 ppm
690 MFL/ml
Average
99.71%
99.97%
99.37%
98.80%
91.93%
76.19%
84.89%
99.95%
* Testedusin9 a flow rate of 0,5 gpm (1.8927I/rain);pressure of 120psig (8.437 Kg/cm2J; p H of Z5_+0,5; t emp. of 68°-+4.5°C (20_2.5°C)
** Measurement in particles/m!
*** NTU = Nephelometric Units
% Reduction
Minimum
99.59%
99.95%
99.37%
97.13%
91.93%
64.28%
67.63%
99.82%
Operating Specifications
_/_ Capacivy: certified for up to 300 gallons (1135 l); up to one year
NPressure
requirement:
40-120
psi (2.8-8.2 bar), non-shock
N'Pemperature:
33°-100°F
(0.6°-38°C)
_ Flow raW: 0.5 gpm (1.9 lpm)
General Installation/Operation/Maintenance
Requirements
_Flush
new cartridge
at flfll flow for 3 miimtes to purge out trapped
ain
_ Replace cartridge when flow becomes
too slow.
Special Notices
_ Installation
instructions;
parts and service availability; and standard
warranty are included with the product when shipped.
_This
drinking
water system must be maintained
according
to manufacturer's
instructions,
including
replacement
of
filter cartridges.
_ Do imt use with ,a-ater that is microbiologically
unsafe or of unknown
quality without adequate
disinR-ction
before or
M_er the sysmm. Systems certified
for cyst reduction
may"be used on disinfected
wamr that may contain
filmrable cysts.
_gThe contaminants
or other substances
removed or reduced
by this water treatment
system are not necessarily in your wam_:
_Check
for compliance
with the state and local laws and regulations.
System
Tested
and
Certified
by NSF international
against
ANSI/NSF
Standard
42 & 53 tor the
reduction
oh
Standard
No.
42: Aesthetic
Effects
Chenfical
Unit
Taste
and
Odor
Reduction
Chlorine
Reduction,
Class
1
Mechanical
Filtration
Unit
Particulate
Reduction,
Class
i
Statadard
No.
53: Health
Effects
Chemical
Reduction
Unit
Lead
and
AtraTine
Reduction
[Jndane
and
2,4-1) Reduclion
Mechanical
Filtration
Unit
"ihrbidily
Reduction
(_st
and Asbestos
Rc<hmtion
Manui:acmred for: General Electric Company, Louisville, KY 40225
38

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents