Frigidaire FRS12PYW10 Use & Care Manual page 18

Table of Contents

Advertisement

4. Flaring work.
Firmly hold copper
pipe in a
die in the dimension
shown in
the table
below.
A (inch)
OUTER
DIAMETER (inch)
Max.
Min.
1/4
0.051
0.028
3/8
0.063
0.039
1/2
0.071
0.039
5/8
0.087
Handle
Clamp
handle
Copper
pipe
Yoke
ow mark
Connection
Adiustment
1. Align the pipes to be connected.
2. Screw the flare nut with your
fingers, and then tighten it with
a spanner and torque wrench,
as shown in the following figure.
Caution: Excessive twisting may
break the nut, depending on the
installation conditions.
Indoor unit
Flare
tubing
nut
Pipings
OUTER
DIAMETER
(inch)
1/4
3/8
1/2
TIGHTENING
TORQUE (Ibf.in)
139
260
434
ADDITIONAL
TIGHTENING
TORQUE (Ibf.in)
174
304
477
5/8
651
694

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents