Frigidaire FRS095YC1 Instruction Manual

Split type room air conditioner inverter

Advertisement

INSTRUCTIONS MANUAL
SPLIT TYPE ROOM AIR CONDITIONER
INVERTER
MODELS:
• FRS095YC1
• FRS095YW1
• FRS125YC1
• FRS125YW1
• FRS185YC2
• FRS185W2
• FRS225YC2
• FRS225YW2
• FAS(C,E)09C6APLW
• FAS(C,E)12C6APLW
• FAS(C,E)18C6APLW
• FAS(C,E)24C6APLW
ATTENTION
Please read this manual completely
before operating your room air conditioner.

Advertisement

Table of Contents
loading

Summary of Contents for Frigidaire FRS095YC1

  • Page 1 INSTRUCTIONS MANUAL SPLIT TYPE ROOM AIR CONDITIONER INVERTER MODELS: • FRS095YC1 • FRS095YW1 • FRS125YC1 • FRS125YW1 • FRS185YC2 • FRS185W2 • FRS225YC2 • FRS225YW2 • FAS(C,E)09C6APLW • FAS(C,E)12C6APLW • FAS(C,E)18C6APLW • FAS(C,E)24C6APLW ATTENTION Please read this manual completely before operating your room air conditioner.
  • Page 2: Table Of Contents

    Welcome to the world of Contents simple handling and no worries. Thank you for choosing Frigidaire. This manual contains all of the information 01. Welcome...................01 required to guarantee your safety and the appropriate use of your air 02. Environmental advices................01 conditioner.
  • Page 3: Safety Precautions

    Safety precautions - Cool/heat and fan only operation To prevent injury to the user or other people and property damage, the - Dry operation following instructions must be followed. - Airflow direction adjustment Incorrect operation due to ignoring of instructions may cause harm or damage. - Sleep mode The seriousness is classified by the following indications.
  • Page 4 conditioner. It contains contaminants together with a stove, etc. An and could make you sick. oxygen shortage may occur. 10.Do not use the power cord close to 21.When the unit is to be cleaned, heating appliances. It may cause switch off, and turn off the circuit fire and electric shock.
  • Page 5: Choosing The Installation Site

    Choosing the Installation Site falling of unit. Precautions for Installation 28.Always insert the filters securely. Installation at the following sites may cause problems. If you must inevitably Clean filter once every two weeks. install the unit at one of these sites, please consult your local distributor Operation without filters may cause beforehand: failure.
  • Page 6: Parts List

    Parts list Outdoor Unit NUMBERING PART NAME QTY. More 1. The outdoor unit must be installed More More Installation plate than 60cm at a convenient site that is not than 30cm than 30cm exposed to strong winds. The site Clip anchor should be dry and well ventilated.
  • Page 7: Indoor Unit Installation

    Indoor unit installation Installation plates and dimensions More than 15cm above 150mm from the ceiling indoor unit outline Installation plate Indoor unit More than 12cm above 120mm above 120mm from the wall from the wall Refrigerant pipe Refrigerant pipe hole (left) Ø 65 hole (right) Ø...
  • Page 8 above 150mm from ceiling 1080 Drilling the Hole Wall 1. Determine the position of the hole for Indoor unit Outdoor unit the pipe using the installation plate and drill the pipe hole so that it is above 120mm titled slightly downward. above 120mm from wall from wall...
  • Page 9 Fastening the Indoor Unit Piping and wrapping Ponding Upper hook 1. Pass the piping through the hole in 1. Bundle the tubing, connecting cable, Indoor unit the wall. and drain hose with tape securely, 2. Put the upper claw at the back of evenly as shown.
  • Page 10: Outdoor Unit Installation

    Outdoor unit installation 1. Install the outdoor part of the unit Settlement of outdoor unit on a rigid surface to avoid excess Anchor the outdoor unit tightly and Air inlet noise and vibration. horizontally on a concrete or rigid mount with a bolt and nut 10 or 8 2.
  • Page 11: Refrigerant Piping Connection

    Refrigerant piping connection 4. Flaring work. Flaring work Main cause for refrigerant leakage is A) Firmly hold copper pipe in a die due to defect in the flaring work. in the dimension shown in the table below. Cooper Carry out correct flaring work using pipe the following procedure: A (mm)
  • Page 12: Electrical Work

    Electrical work Connect the cable to the indoor unit Electric safety regulations for the initial Installation 1. The inside and outside connecting 1. If there is serious safety problem 5. According to the attached Electrical cable can be connected without about the power supply, the Connection Diagram located on the Electrical box...
  • Page 13 Connect the cable to the outdoor unit 9000 and 18000 Btu's 9000 and 18000 Btu's COOLING MODEL HEATING AND COOLING MODEL 1. Remove the electrical control board "Connector A" "Connector B" "Connector A" "Connector B" cover from the outdoor unit by Terminal block of indoor unit Terminal block of indoor unit loosening the screw.
  • Page 14: Air Purging

    Caution After the confirmation of the above conditions, prepare the wiring as follows: 9000 and 18000 Btu's 9000 and 18000 Btu's 1. Never fail to have an individual power circuit specifically for the air COOLING MODEL HEATING AND COOLING MODEL conditioner.
  • Page 15 Air purging with vacuum pump When using the vacuum pump For method of using a manifold valve, refer to its operation manual. 1. Check that each tube(both liquid and gas side tubes) between the indoor and outdoor units have been properly connected and all wiring for the test 1.
  • Page 16: Electrical Safety

    Electrical safety Test running Perform test operation after completing gas leak check at the flare nut Perform the electric safe check after completing installation: connections and electrical safety check. 1. Insulated resistance: The insulated resistance must be more than 2M 2.
  • Page 17: Preparing The Device For Operation

    Preparing the device for operation Product description 1. Contact a specialist to install the device. 2. Guarantee that the unit is appropriately fastened and complies with all of the Front panel frame aforementioned safety norms. Front panel 3. Before operating the air conditioner, ensure that the air filter is installed Air filter correctly.
  • Page 18: Remote Control

    Remote control Display panel Remote control operation (indoor unit) 1. Operation mode: Cool, Heat (Only for AUTO indicator: This indicator the models with cool/heat), DRY, FAN, illuminates when the air conditioner and AUTO (Automatic). is in AUTO operation. 2. Timer 24 hrs. DEFROST indicator (For Cooling 3.
  • Page 19: When Should The Batteries Be Replaced

    Remote control description When should the batteries be 3. When selecting the function of timer, the remote control sends replaced ON/OFF: Push this button to start (automatically) a signal to the 1. When there is not a “beep” the unit operation. Push the button indoor unit at the specific moment.
  • Page 20: Temp. Increase

    LCD display indicators timed setting in 30 minutes the preset temperature in the increments. When the setting time shortest time.O n c ooling m ode,t displays 10:00, each press will he u nit w ill b low s trong co oling increase the auto-timed setting 60 air with super high fan speed.
  • Page 21: How The Air Conditioner Works

    How the air conditioner works Attention Automatic operation DRY operation When the Air Conditioner is ready for use, switch on the power and the The dry mode will automatically select Due to the difference of the set the drying operation based on the OPERATION indicator lamp on the display panel of the indoor unit starts temperature of the unit and the flashing.
  • Page 22 SLEEP mode To set the stopping time Attention Press the sleep button to activate the 1. Push the TIMER OFF button and the remote controller will show TIMER OFF, sleep mode. To deactivate, press the the last set time for the stopping operation and the signal "h" will be shown button again.
  • Page 23: How To Use The Indoor Unit

    How to use the indoor unit Adjusting air flow direction The AIR DIRECTION and SWING buttons will be disabled when the air conditioner Adjust the air flow direction properly is not in operation (including when the otherwise, it might cause discomfort TIMER ON is set).
  • Page 24 Manual operation (without remote control) Maintenance Cleaning the indoor unit and remote Manual operation can be used controller temporarily in case you can not find the remote controller or its batteries 1. It is necessary to stop the air are exhausted. conditioner and disconnect the power 1.
  • Page 25: Operation Tips

    Operation tips vacuum cleaner or water. After, dry for The following events may occur during normal operation. Support a couple of hours or until dry. Fresh frame air filter 7. Insert the fresh air filter in its original place. Protection of the air conditioner. 8.
  • Page 26: Solutions For Problems

    Solutions for problems A peculiar smell comes out from the indoor unit. If your air conditioner malfunctions, check the following information to find This is caused by the indoor unit giving off smells permeated from building solutions or probable causes of the failure. Do not try to repair the unit by material, from furniture, or smoke.
  • Page 27: Technical Specifications

    Technical specifications COOL ONLY MODELS HEATING + COOLING MODELS FASC09C6APLW FASC12C6APLW FASC18C6APLW FASC24C6APLW FRS095YC1 FRS125YC1 FRS185YC2 FRS225YC2 OUTDOOR UNIT OUTDOOR UNIT FASE09C6APLW FASE12C6APLW FASE18C6APLW FASE24C6APLW FRS095YW1 FRS125YW1 FRS185W2 FRS225YW2 INDOOR UNIT INDOOR UNIT Cool Heat & Cool Cool Cool Cool Heat &...
  • Page 28 Notes Notes...