Summary of Contents for Frigidaire FRS093LW1

  • Page 1 All about the Installation of your Split Type Room Air Conditioner Model(indoor/outdoor): FRS093LW1/FRS093LC1 FRS123LW1/FRS123LC1 r f . r f .
  • Page 2: Safety Precautions

    Safety precautions This appliance must be installed by a qualified licensed HVAC technician in accordance with all applicable codes. All electrical connections should be performed by a licensed electrician. DANGER! Avoid Serious Injury CAUTION! Avoid Injury or or Death damage to the unit or other property 1.
  • Page 3 To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. 1. Connect with the power properly. Otherwise, it may cause electric shock or fire due to excess heat generation.
  • Page 4 11.Do not open the unit during operation. It may cause electric shock or injury. 12.Do not drink water drained from air conditioner. It contains contaminants and could make you sick. 13.Do not disassemble or modify unit. It may cause failure of appliance and electric shock.
  • Page 5: Choosing The Installation Site

    Choosing the installation site Installation Warnings 1. Carefully read the installation manual before beginning. 2. Follow each step as shown. 3. Observe all local, state and national electric codes. This appliance must be installed by a qualified licensed HVAC technician in accordance with all applicable codes.
  • Page 6: Outdoor Unit

    Outdoor Unit More More More than 2 feet than 1 feet than 1 feet 1. The outdoor unit must be installed at a convenient site that is not exposed to strong winds. The site should be dry and well ventilated. 2.
  • Page 7: Parts List

    Parts list NUMBER PART NAME Installation plate Clip anchor Self-tapping screw A #7 X 1" Seal Drain Joint Connecting cable (capacity < 12000 Btu's) Ø1/4" Liquid side (capacity > 12000 Btu's) Ø3/8" Connecting pipe Ø3/8" (capacity < 9000 Btu's) assembly Gas side Ø1/2"...
  • Page 8 More than 6" Indoor unit More than 5" More than 5" Air filter More than 2 feet More than 1 feet More than 2 feet More than 6.6 feet Outdoor unit Attention 1. This illustration is for explanation purposes only. 2.
  • Page 10: Indoor Unit Installation

    6" or more from the ceiling Installation plate Indoor unit outline 5" or more 5" or more from the wall from the wall 1.77" 3.55" Refrigerant pipe Refrigerant pipe hole (right) Ø 2.56" hole (left) Ø 2.56" 3.15 19.27" 36.25" Capacity <...
  • Page 11 Connective pipe and drainage installation Connective pipe Pipe cover Pipe Pipe cover (right) holder (left) 1. For the left-hand and right-hand piping, remove the pipe cover from the side panel. The pipe cover Left piping must be kept as it may be used when relocating the air...
  • Page 12 3. Piping can easily be made by lifting the indoor unit with a cushioning material between the indoor unit and the wall. Get it out after finish piping. 4. Push the lower part of the indoor unit up on the wall, Then move the indoor unit from side to side, up and down to check if it is Cushioning...
  • Page 13: Outdoor Unit Installation

    Outdoor unit installation 1. Install the outdoor part of the unit on a rigid surface to avoid excess noise and vibration. 2. Direct the air vent toward an area without obstacles. 3. Install the unit at the site where it is exposed to as little wind as possible, especially in areas where it is frequently windy.
  • Page 14 Settlement of outdoor unit Air inlet Anchor the outdoor unit tightly and horizontally on a concrete or rigid inlet mount with a bolt and nut 0.39 inch or 0.32 inch diameter (Purchasedy separately). Air outlet A (inch) B (inch) Outdoor unit dimension inch(WxHxD) 2.30'x1.76'x0.77' 1.50' 0.82'...
  • Page 15: Refrigerant Piping Connection

    Refrigerant piping connection Unit comes with 16.4 feet tubing bundle. It is not recommended to cut. If too long, loop for excess. Note: Keep original bend so not kinking of the tube occurs. Flaring work Main cause for refrigerant leakage is due to defect in the flaring work.
  • Page 16: Flaring Work

    4. Flaring work. Firmly hold copper pipe in a die in the dimension shown in Copper the table below. pipe Handle A (inch) OUTER Yoke DIAMETER (inch) Min. Max. 0.028 Red arrow mark 0.051 0.039 0.063 0.071 0.039 Clamp 0.087 0.095 handle Connection Adjustment...
  • Page 18: Electrical Work

    Connect the cable to the indoor unit Electrical box cover 1. The inside and outside connecting cable can be connected without removing the front grille. 2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed flexible cord, type designation 16AWG or heavier cord.
  • Page 19 9000 and 12000 Btu's 9000 and 12000 Btu's COOLING MODEL HEATING AND COOLING MODEL Terminal block of indoor unit "Connector A" "Connector B" Terminal block of indoor unit 1 2(N) 3 4 1 2(N) 3 4 To Outdoor Unit To outdoor To outdoor unit unit...
  • Page 20 Connect the cable to the outdoor unit 1. Remove the electrical control board cover from the outdoor unit Cover by loosening the screw. 2. Connect the connective cables to Screw the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor units.
  • Page 21 9000 and 12000 Btu's 9000 and 12000 Btu's COOLING MODEL HEATING AND COOLING MODEL "Conector A" "Conector B" Terminal block of outdoor unit Terminal block of outdoor unit 2(N) 2(N) Cables Cables board Cord clamp board "Conector C” "Conector D” Terminal block of outdoor unit To power supply To indoor unit...
  • Page 22: Air Purging

    Caution After the confirmation of the above conditions, prepare the wiring as follows: 1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover. 2.
  • Page 23: Air Purging With Vacuum Pump

    Air purging with vacuum pump 1. Check that each tube(both liquid and gas side tubes) between the indoor and outdoor units have been properly connected and all wiring for the test run has been completed. Remove the service valve caps from both the gas and the liquid side on the outdoor unit.
  • Page 24 When using the vacuum pump For method of using a manifold valve, refer to its operation manual. Indoor unit 1. Completely tighten the flare nuts at connection point A, B, C and D. Connect valve core removal tool to the charging port, then connect Outdoor unit vacuum hose to valve core tool.
  • Page 25: Electrical Safety

    Electrical safety Perform the electric safety check after completing installation: 1. Insulated resistance: The insulated resistance must be more than 2M 2. Grounding work: After finishing grounding work, measure the grounding resistance by visual detection and grounding resistance tester. Make sure the grounding resistance is less than 4 3.
  • Page 26: Test Running

    Test running Perform test operation after completing gas leak check at the flare nut connections and electrical safety check. 1. Connect the power, press the ON/OFF button on the remote controller to turn the unit on. 2. Use the MODE button to select COOL, HEAT(Only for models with heating function), AUTO and FAN to check if all the functions work well.
  • Page 27: Preparing The Device For Operation

    Preparing the device for operation 1. Contact a specialist to install the device. 2. Guarantee that the unit is appropriately fastened and complies with all of the aforementioned safety norms. 3. Before operating the air conditioner, ensure that the air filter is installed correctly.

This manual is also suitable for:

Frs123lw1Frs123lc1Frs093lc1