Frigidaire FRS09PYS1 Installation Manual

Installation instructions (all languages)
Hide thumbs Also See for FRS09PYS1:

Advertisement

Installation
Installation warnings:
1. Carefully read the installation manual before beginning.
2. Follow each step as shown.
3. Observe all local, state, and national electrical codes and by qualified,
licensed, authorized personnel only.
4. Pay attention to danger and safety notices

Choosing the installation site

Precautions for Installation
Installation at the following sites may cause problems. If you must inevitably install
the unit at one of these sites, please consult your local distributor beforehand:
1. Sites with machine oil.
2. Sites with a high concentration of salinity, such as coastal areas.
3. Sites with sulfuric gas, such as hot water springs.
4. Sites with high frequency equipment, such as wireless equipment, welding
machines and medical installations.
5. Sites with flammable gases or volatile material.
6. Sites with special environmental conditions.
7. Laundry rooms.
Indoor Unit
1. The unit must be installed at a site
that does not obstruct the flow of
air.
2. The site must support the weight of
the indoor unit.
3. The site must be easily accessible
for maintenance and replacement
of the air filter.
4. The site must allow for the
necessary space around the indoor
unit, as shown in the sideward
figure.
5. There should be at least 3 feet (1
meter) between the unit and radio
or television devices. It is ideal
that the unit be installed at the
center.
6. It must be far from fire, smoke or
flammable gases.
7. The indoor unit must be at least 8.2
ft(2.5 meters) from the ground.
8. The site must allow for the easy
removal of the connector pipe and
drain hose.
9. The unit must be installed at a site
protected from direct sunlight.
More
than 6"
More
than 8 .2'
Choosing the installation site
More
than 6"
More
than 6"
06

Advertisement

Table of Contents
loading

Summary of Contents for Frigidaire FRS09PYS1

  • Page 1: Choosing The Installation Site

    4. Pay attention to danger and safety notices Choosing the installation site Precautions for Installation Installation at the following sites may cause problems. If you must inevitably install the unit at one of these sites, please consult your local distributor beforehand: 1. Sites with machine oil.
  • Page 2 More than 6.6' of increased noise and vibration than 1.65' at the site. 4. The unit must be installed at a site where the noise produced by its operation and air discharge does not disturb the neighbors or animals. 5. The site cannot have any leakage of flammable gases.
  • Page 3: Parts List

    Ø3/8" assembly Gas side Ø1/2" (capacity < 18000 Btu's) (capacity > 24000 Btu’s) Ø5/8" capacity = 18000 Btu's Drainage Plug capacity = 21500 Btu s Remote Controller holder Self-tapping screw B #4 X 3/8" Indoor unit Outdoor unit Parts list...
  • Page 4 More than 6" More than 6" Air filter More than 1.65' More than 1' More than 1.65' More than 6.6' Outdoor unit Attention 1. This illustration is for explanation purposes only. 2. Copper tubes must be insulated independently Parts list...
  • Page 5: Indoor Unit Installation

    Indoor unit installation Installation plates and dimensions 6" or more from Installation plate the ceiling Indoor unit outline 6" or more 6" or more from the wall from the wall Refrigerant pipe Refrigerant pipe hole (right) Ø 2.56" hole (right) Ø 2.56"...
  • Page 6 Fit the Installation Plate and drill holes in the figures above. in the wall according to the wall structure and corresponding mounting 2. In the case of tiled, concrete or points on the installation plate similar walls, create 0.2" (Dimensions are in “mm” unless diameter holes.
  • Page 7 Upper hook 1. Pass the piping through the hole in the wall. 2. Put the upper claw at the back of the indoor unit on the upper hook of the installation plate, move the indoor unit from side to side to see that it is securely hooked.
  • Page 8 4. Both of the auxiliary piping should be heat insulation. 5. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side may cause drain pan to overflow inside the unit.
  • Page 9: Outdoor Unit Installation

    2. Direct the air vent toward an area without obstacles. 3. Install the unit at the site where it is exposed to as little wind as possible, especially in areas where it is frequently windy.
  • Page 10 . Installation method:Insert the drain connection into one of the 25 holes of the chassis and then connect drainage pipe with Ø drain nozzle. Insert drainage plugs into the other holes (Only for 12000Btu's).
  • Page 11: Refrigerant Piping Connection

    Refrigerant piping connection Unit comes with 16.4' tubing bundle. It is not recommended to cut. If too long, loop for excess. Note: Keep original bend so not kinking of the tube occurs. Flaring work Main cause for refrigerant leakage is due to defect in the flaring work.
  • Page 12: Flaring Work

    0.039 Clamp 0.087 0.095 handle Connection Adjustment 1. Align the pipes to be connected. Caution: Excessive twisting may 2. Screw the flare nut with your break the nut, depending on the fingers, and then tighten it with installation conditions. a spanner and torque wrench, as shown in the following figure.
  • Page 13: Electrical Work

    SIZE < 9000 Btu's 25A/25A 115V~/ 60Hz 9000 Btu's < capacity < 12000 Btu’s 25A/25A 115V~/ 60Hz 25A/25A 208/230V~/ 60Hz > 12000 Btu's Note: The supply voltage must be consistent with the rate voltage of the air conditioner. Electrical work...
  • Page 14 Connect the cable to the indoor unit Electrical box 1. The inside and outside connecting cover cable can be connected without removing the front grille. 2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed flexible cord, type designation 16AWG or heavier cord.
  • Page 15 Connect the cable to the outdoor unit Remove the electrical control board cover from the outdoor unit by loosening the screw. 2. Connect the connective cables to the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor units.
  • Page 16: Air Purging

    3. Specification of power source. 4. Confirm that electrical capacity is sufficient. 5. See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate. 6. Confirm that the cable thickness is as specified in the power source specification.
  • Page 17 Do not try to open it further. 2. Operation of closing packed valve: Securely tighten the valve stem with a special tool. Then securely tighten the valve stem cap with a spanner or the like. Refer to tightening torque table in page 17...
  • Page 18 When using the vacuum pump For method of using a manifold valve, refer to its operation manual. 1. Completely tighten the flare nuts at Indoor unit connection point A, B, C and D. Connect valve core removal tool to the charging port, then connect Outdoor unit vacuum hose to valve core tool.
  • Page 19: Electrical Safety

    Electrical safety Perform the electric safety check after completing installation: 1. Insulated resistance: The insulated resistance must be more than 2M 2. Grounding work: After finishing grounding work, measure the grounding resistance by visual detection and grounding resistance tester. Make sure the grounding resistance is less than 4 3.
  • Page 20: Test Running

    Perform test operation after completing gas leak check at the flare nut connections and electrical safety check. 1. Connect the power, press the ON/OFF button on the remote controller to turn the unit on. 2. Use the MODE button to select COOL, HEAT(Only for models with heating function), AUTO and FAN to check if all the functions work well.
  • Page 21: Preparing The Device For Operation

    3. Before operating the air conditioner, ensure that the air filter is installed correctly. 4. If the unit has been out of use for a long period of time, it is recommended that the air filter be cleaned before use. During continuous use, clean the air filter every two weeks.

This manual is also suitable for:

Frs12pys1Frs184ys2Frs18pys2Frs224ys2Frs22pys2

Table of Contents