Adjustment Section: Pages; Travel Limit Adjustments - Craftsman 139.53978SRT Owner's Manual

1/2 hp
Table of Contents

Advertisement

Adjustment Section: Pages 28 - 30
Adjustment Step 1
Adjust
the UP and DOWN
Limits
Do not make any limit adjustments
until the
safety reversing sensors are completely
installed.
Limit adjustment settings regulate the points at
which the door will stopwhen
moving up or down.
If anything interferes with the door's upward travel, it
will stop. If anything interferes with the door's
downward travel (including binding or unbalanced
doors), it will reverse.
To operate the opener, press the Door Control push
bar or button. Run the opener through a complete
travel cycle.
• Does the door open and close completely?
• Does the door stay closed and not reverse
unintentionally when fully closed?
If your door passes both of these tests, no limit
adjustments are necessary unless the reversing test
fails (See page 30).
Adjustment
procedures are outlined below.
Read the procedures carefully before
)roceeding to Adjustment Step 2. Use a
screwdriver to make limit adjustments.
Run the
opener through a complete travel cycle after
each adjustment.
NOTE: Repeated operation of the opener during
adjustment procedures may cause the motor to
overheat and shut off. Simply wait 15 minutes and
try again.
Improper
adjustment
of the travel limits
will
interfere with the proper operation of the safety
reverse
system.
The door might not reverse
properly
when required
and could seriously
injure or kill someone
under it. Test the safety
reverse system following all adjustments to the
travel limits. See page 30.
Limit
Adjustment
I_
Screws
"................
llllhlllll, 0 0 0
0 0
Cover
Left Side Panel
Protection
Bolt
Adjustment Label
How and When to Adjust the Limits
• If the door does not open completely, but
opens at leastfive feet:
Increase up travel. Turn the UP limit adjustment
screw clockwise. One turn equals 2" of travel,
NOTE: To prevent the trolley from hitting the cover
_rotection bolt, keep a minimum distance of 2-4"
between the trolley and the bolt.
• If door does not open at least 5 feet:
Adjust the UP (open) force as explained in
Adjustment Step 2.
• If the door does not close completely:
Increase down travel. Turn the DOWN limit
adjustment screw counterclockwise. One turn
equals 2" of travel.
If the door still won't close completely and the trolley
bumps into the trolley stop bolt (see page 4 or 5), try
lengthening the door arm (see page 26) and
decreasing the down limit.
• If the opener reverses in fully closed position:
Decrease down travel. Turn the DOWN limit
adjustment screw clockwise, One turn equals 2" of
travel.
• If the door revereeswhen
closing and
there is no visible interference to travel cycle:
If the opener lights are flashing, the Safety
Reversing Sensors are either not installed,
misaligned, or obstructed. See Troubleshooting,
page 23.
Test the door for binding: Pull the emergency
release handle. Manually open and close the door. If
the door is binding, call for garage door service. If
the door is not binding or unbalanced, adjust the
DOWN (close) force. See Adjustment Step 2.