Autoraid Manager Components - HP Surestore Disk Array 12h - And FC60 System Administrator Manual

System administrator's guide for hp-ux, mpe, and windows nt
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Managing the HP SureStore E Disk Array 12H on Windows NT

AutoRAID Manager Components

AutoRAID Manager Components
AutoRAID Manager software includes several components. The AutoRAID Manager Server and the
AutoRAID Manager Client are required components that work together to manage the HP SureStore E Disk
Array 12H. The exact combination of components you install will be determined by your system and
network configuration.
AutoRAID Manager Clients - these required components provide the user interface for managing the
HP SureStore E Disk Array 12H. Two clients are provided: the AutoRAID Manager for Windows
client and the ARM command line utilities. The Windows client can be used to manage disk arrays
remotely. The command line utilities can only be used to manage disk arrays from the host server.
OpenView Client for AutoRAID - this optional component runs under HP OpenView and
automatically discovers and displays HP AutoRAID devices on the HP OpenView map. The HP
OpenView client communicates with the SNMP agent. The OpenView Client is installed if OpenView
Network Node Manager is installed on the client.
AutoRAID Manager Server - this required component is the core of the AutoRAID Manager. The
AutoRAID Manager Server (ARMServer) is installed as a service on the host server to which the disk
array is connected. The HP AutoRAID Manager service must be running to manage disk arrays using
AutoRAID Manager. Installation of the AutoRAID Manager Server must be done from the host server
console by a user with Administrator access.
Remote Management SNMP Agent - This optional component is installed on the server only if
SNMP is installed. The AutoRAID Manager SNMP agent communicates with the HP OpenView client
to provide the mechanism for broadcasting event information to network administrators and establish a
communication link between the server and the client.
Failover Driver - this componentenables the operating system to exploit the performance and
redundancy benefits provided by dual disk array controllers. During normal operation, the failover
driver manages the transfer of host data to achieve optimum performance. If one of the controllers fails,
the failover driver automatically stops using the failed controller and directs all subsequent I/Os to the
remaining controller. The failover driver provides the same functionality regardless of whether the two
disk array controllers are on the same SCSI channel or on separate SCSI channels.