HP Surestore Disk Array 12h - And FC60 System Administrator Manual page 61

System administrator's guide for hp-ux, mpe, and windows nt
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

3.
Load the controller firmware.
download -C firmware.file 000000123456
4. Reactivate the volume group.
vgchange -a y /dev/vg02
5.
Mount the logical volumes.
mountall
If the disk array has LUNs that are being used as raw devices, for example a database system doing "raw"
I/O, the array should be disconnected from all systems except the one doing the download. An alternative to
disconnecting the systems is to use the HP-UX shutdown (1m) command to halt the other systems until
the download is complete.
Using the ARM Command Line Utilities for HP-UX
Downloading Firmware
61