TROUBLESHOOTING

SYMPTOM
Pilot will not light
Front or rear burner
won't light
Burner not hot enough
NOTE: There are no user serviceable components in the burner assemblies or in the control valves.
In all cases of damage or malfunction, contact your Authorized Wells Service Agency for repairs.
POSSIBLE CAUSE
Gas supply off
Air in lines
Pilot valve not on
Pilot burner holes are plugged
Actuator not depressed
Pilot flame not lit
Control not on
Water in burner
Damaged temperature control
valve, burner, actuator valve or
other internal component
Control valve not set
Shutter or nozzle out of
adjustment
Damaged temperature control
valve, burner actuator or other
internal component
10
SUGGESTED REMEDY
Check main / unit gas valves
Turn gas valve on. Attempt to
light pilot every 15 sec.
Turn pilot valve on / adjust
Clean pilot burner
Burner should light only when a
pot or pan depresses actuator.
Be sure actuator is properly
assembled to arm
Turn off gas — allow unit to
vent for 5 minutes. Turn gas
back on and light both pilots
Turn temperature control to HI
Set to desired setting when lit
Remove burner and dry
thoroughly
Contact Authorized Wells
Service Agency for repairs
Adjust for desired temperature
Contact qualified technician for
adjustment
Contact Authorized Wells
Service Agency for repairs