Fillfueltankwithclean,fresh,unleaded gasoline.
Becareful n otto overfill. A llowabout1/2"tank
spaceforfuelexpansion.
1/2"Air
Space
Tank
Fuel
Install fuel cap and wipe up any spilled gasoline.
IMPORTANT:
It is important to prevent gum deposits
from forming in essential fuel system parts such as the
carburetor, fuel filter, fuel hose or tank during storage.
Also, experience indicates that alcohol-blended
fuels
(called gasohol, ethanol or methanol) can attract
moisture, which leads to separation and formation of
acids during storage. Acidic gas can damage the fuel
system of an engine while in storage. To avoid engine
problems, the fuel system should be emptied before
storage of 30 days or longer. See "Storage" on
page 17. Never use engine or carburetor cleaner
products in the fuel tank or permanent damage may
Occur.
TO START THE ENGINE
_
ARNING!
Never start or stop engine with
electrical devices plugged into the panel
receptacles and turned on.
Unplug all electrical loads from generator
receptacles before starting the engine.
Make sure the unit is in a level position.
Open the fuel shut-off valve.
t
Turn Clockwise to
"OFF" Position
Locate the idle control on/off switch on the control
panel and set it to the "Off" position.
IDLE
OFF
position
J
Place the Run/Stop Switch in the "Run" position.
IGNITION
RUN
position
Pull engine choke out to close choke. DO NOT
FORCE. If the engine is warm, you may not need
as much choking.
DANGER!
Never run engine indoors or in
enclosed poorly ventilated areas. Engine
exhaust contains carbon monoxide, an odorless
and deadly gas.
_
ANGER!
Temperature of muffler and nearby
areas may exceed 150°F (65°C). Avoid these
areas on the generator.
,_
WARNING!
If starting the engine with the
electric starter, always operate the engine with
the battery connected. This ensures that the
battery will be recharged.
When the engine starts, OPEN the choke gradually
as engine warms up up by pushing in on the choke
handle.
Set the idle control on/off switch to the "On"
position.
Electric
Starting
Press the Run/Stop switch to the "RUN" position,
Press the electric start button, located on the
generator cradle opposite the control panel, until
engine cranks.
Use short starting cycles (15 sec. per min.) to
prolong starter life. Extended cranking can damage
starter motor.