WIRE CONTROL OPERATION

SAVE setting

GREE_cassette_eng.indd 8
When the unit is shut off, press the FAN button and
the ( ) button continuously for 5 seconds to activate
the SAVE setting menu. The "SAVE" and "COOL" will
be displayed. (For the first setting, the initial value
will be displayed :26). The lower limit temperature
will be displayed on the set temperature area and the
temperature value will be flashed.
Press ( )and( )buttons to set the cooling lower limit
temperature (The setting range: 6-30).
Press ON/OFF button to confirm the setting.
Press ( ) and ( ) buttons to set cooling upper limit
temperature and the temperature value will flash on the
ambient temperature area (The setting range: 6-30).
Press ON/OFF button to confirm the setting.
Press MODE button to complete the SAVE setting in
COOL and DRY modes, and turn to the SAVE setting in
HEAT mode. The "SAVE" and "HEAT" will be displayed.
After setting is completed, press the FAN and ( ) buttons
for 5 seconds to exit the SAVE setting menu. If the SAVE
interface has been opened, the system will respond to
the last button input after 20 seconds, there is no any
operation, the system will quit the menu, and return to
the normal unit off display.
After the above settings are completed, the "SAVE" will
be displayed. The set temperature will not exceed the
temperature range of the SAVE setting. For example, the
lower cooling limit is set to 23˚C and the upper cooling
limit is set to 27˚C, so the cooling temperature can only
be selected between 23˚C to 27˚C by the wire control or
the remote controller.
To cancel the SAVE setting, press the FAN and ( )
buttons for 5 seconds when the unit is turned off. The
former setting data will not clear, and the next time SAVE
setting will be the initial setting temperature.
NOTE:
• The upper limit temperature should not be lower
than the setting lower limit temperature. If upper limit
temperature is lower than the lower limit temperature,
the system will default the higher as the upper limit
temperature, the lower as the lower limit temperature.
• If the upper limit temperature is the same as the lower
limit temperature, the system can only operate at this
temperature under corresponding mode.
• After the unit is disconnected to power supply, the
SAVE settng will be memorized. The next time power
on, the SAVE setting is still active.
• If the SAVE mode is set, the sleep mode and AUTO
mode will be invalid.
E-8