Errdisplayfilter - HP StorageWorks 8B - FC Entry Switch Reference Manual

Fabric os reference manual (version 3.0)
Hide thumbs Also See for StorageWorks 8B - FC Entry Switch:
Table of Contents

Advertisement

errDisplayFilter

Display or set the level of error filtering.
Synopsis
errDisplayFilter [level]
Availability
All users (display)
admin (set)
Description
Use this command to view or configure the error levels that are displayed on the front panel. Errors
with a higher level (lower severity) than the value specified are stored in the error log but are not
displayed on the front panel.
Note:
Operands
This command has the following operand:
level
When the command is used with no operand, the current level is displayed.
Example
To display the current filter level, then change it to 3:
Note:
See Also
errLogShow
Fabric OS Reference
This command can only be used on a switch with a front panel display.
Specify the new error filtering level. Valid values are:
1 = critical
2 = error
3 = warning
4 = information
5 = debug
Only error levels equal or lower (equal or more severe) than the specified value
are displayed. This operand is optional.
switch:admin> errDisplayFilter
All errors will be reported on the front panel.
switch:admin> errDisplayFilter 3
Committing configuration...done.
This example specifies that only errors of severity 1 though 3 are displayed.