Operating Temperature - York YUKC 07-18 Installation & Owner's Manual

Minisplit air blower
Table of Contents

Advertisement

Outdoor Unit Multi Inverter RRJC 18-27
Model
Indoor Units Combination
Power supply
Capacity
Cooling
Input
Rated current
Capacity
Heating
Input
Rated current
Max. input
Max. current
Type
Input
Rated current (RLA)
Compressor
Locked rotor Amp (LRA)
Thermal protector
Capacitor
Refrigerant oil
Input
Outdoor fan
Capacitor
motor
Speed
Number of rows
Fin spacing
Fin type
Outdoor coil
Tube outside dia.
Tube Material
Coil length x height x width
Number of circuits
Outdoor air flow
Outdoor noise level
Dimension (WxHxD)
Outdoor
Packing (WxHxD)
unit
Net/Gross weight
Refrigerant Type R-410A
Liquid side/ Gas side
Transfer Connector (9.53→12.7)
Refrigerant
piping
Max. refrigerant pipe length
Max. difference in level
Remark : The above design and specifications are subject to change without prior notice for product improvement.

OPERATING TEMPERATURE

Temperature
Room temperature
Outdoor temperature
CAUTIONS
1. If air conditioner is used outside of the above conditions, certain safety protection features may come into operation
cause the unit to function abnormally.
2. Room relative humidity less than 80%. If the air conditioner operates in excess of this figure, the surface of the
air conditioner may attract condensation. Please set the vertical air flow louver to its maximum angle (Vertically to
the floor), and set HIGH fan mode.
3. Optimum performance will be achieved within these operating temperature.
8
ENGLISH
J368-EN.indd 8
Single
Ph-V-Hz
1Ph, 220-240V~, 50Hz
Btu/h
7,000~12,000
W
2,050~3,517
W
1,000~1,300
A
4.8~6.5
Btu/h
9,000~14,000
W
2,638~4,103
W
1,300~1,600
A
6.3~7.8
W
A
W
A
A
µF
ml
W
µF
r/min
mm
Hydrophilic aluminium
mm
mm
m
/h
3
dB(A)
mm
mm
kg
g
mm
mm
m
15 (each indoor unit)
m
10 (each indoor unit)
Mode
Cooling operation
17°C~32°C
21°C~43°C
RRJC 18AA-AAA
Double
Single
18,000
7,000~12,000
5,275
2,000~3,500
1,813
1,000~1,300
11.5
4.8~6.5
21,000
10,000~14,000
6,155
2,900~4,100
2,038
1,300~1,600
11.0
6.3~7.8
3,200
20
Rotary inverter
1,690
11.6
60
Internal
85µF/250V
750
148
3
775
2
1.7
Ø9.53
Innergroove tube
776×660×22
2
2,500
60
845X695X335
965X772X405
71/74
2,100
Ø6.35/Ø9.53
2
Heating operation
0°C~30°C
-7°C~24°C
RRJC 27AA-AAA
Double
Treble
1Ph, 220-240V~, 50Hz
16,000~24,000
27,000
4,690~7,000
7,913
2,570~2,850
2,806
11.7~13.5
13.5
24,000~27,000
30,000
7,000~7,900
8,792
2,100~2,750
2,739
11.0~13.2
13.2
3,200
20
Rotary inverter
1,690
11.6
60
Internal
85µF/250V
750
148
3
775
2
1.7
Hydrophilic aluminium
Ø9.53
Innergroove tube
776×660×22
2
2,500
60
845X695X335
965X772X405
72/76
2,250
3 X Ø6.35/Ø9.53
2
15 (each indoor unit)
10 (each indoor unit)
Drying operation
17°C~30°C
11°C~43°C
2/1/07 9:40:57 AM