Casio E-Con EA-200 User Manual page 15

For classpad 300; classpad 300 plus
Hide thumbs Also See for E-Con EA-200:
Table of Contents

Advertisement

Basic Steps for Configuring Sampling Parameters
k Photogate Sensor Parameters
Connection of a Vernier Photogate to the EA-200 requires configuration of parameters that
are different from those for other types of sensors.
u To configure a setup for Photogate alone
In step (3) of the procedure under "To configure parameters for sampling with a single
sensor" on page 2-1, select [Photogate] on the [Vernier] tab for the sensor. This causes the
parameters described below to appear on the Sensor Setup window that appears in step (4).
Parameter
(Channel)
Gate Status
Number of Samples
Store List
Folder
Data
Interval
Count
2-5
Initial Default
SONIC
CH1:
SONIC: Select this option when the Photogate
Open-Open
Open-Open: Timing starts when the gate opens, and
Open-Close: Timing starts when the gate opens, and
Close-Open: Timing starts when the gate closes,
Close-Close: Timing starts when the gate closes,
10
Input an integer in the range of 1 to 1000 to
specify the number of samples.
EConSamp
Specify the variable folder for storage of interval data
and count data.
Interval
Input a variable name up to eight characters long for
storage of interval data.
Count
Input a variable name up to eight characters long for
storage of count data.
20031201
Description
Select this option when the Photogate
sensor is connected to CH1.
sensor is connected to SONIC.
continues until it closes and then opens
again.
continues until it closes.
and continues until it opens.
continues until it opens, and then closes
again.