Casio E-CON Software Manual

For the algebra fx 2.0 series

Advertisement

Quick Links

E-CON Ver. 1.20
Software for the ALGEBRA FX 2.0 Series
1. E-CON Overview
2. EA-100 Setup
3. Setup Memory
4. Program Converter
5. Starting a Sampling Operation
All of the explanations provided here assume that you are already familiar
with the operating precautions, terminology, and operational procedures of
the calculator and the EA-100.
Chapter

Advertisement

Table of Contents
loading

Summary of Contents for Casio E-CON

  • Page 1 E-CON Ver. 1.20 Software for the ALGEBRA FX 2.0 Series 1. E-CON Overview 2. EA-100 Setup 3. Setup Memory 4. Program Converter 5. Starting a Sampling Operation All of the explanations provided here assume that you are already familiar with the operating precautions, terminology, and operational procedures of the calculator and the EA-100.
  • Page 2: E-Con Overview

    • 6(HELP) ... Displays E-CON help. • Pressing the K key (Setup Preview) or a cursor key while the E-CON main menu is on the screen displays a preview dialog box that shows the contents of the setup in the current setup memory area.
  • Page 3: Ea-100 Setup

    2. EA-100 Setup You can use the E-CON Mode to set up the EA-100 for sampling and then start sampling immediately or save the setup in calculator memory. You can use either of the following two methods to set up the EA-100.
  • Page 4 4. Press any key to start Setup Wizard and display the sensor specification screen. • Press 1 to specify a CASIO sensor, or 2 to specify a VERNIER sensor. From the menu of supported sensors that appears, select the one you want.
  • Page 5 • 4(PRGM) ... Converts the setup to a program (page 4-1). • Pressing 2(NO) in step 7 returns to the E-CON main menu and stores the setup in the E-CON Mode’s current setup memory area. You can use the following function key operations from the E-CON main menu to manipulate the contents of the current setup memory area.
  • Page 6 The following procedure describes the general steps for using Advanced Setup. Refer to the pages as noted for more information. 1. Display the E-CON main menu. 2. Press 1(SETUP). This displays the “Setup EA-100” sub-menu. 3. Press c(Advan). This displays the Advanced Setup menu.
  • Page 7 • You can return the settings on the above setup screens (b through e) using the procedure described under “To return setup parameters to their initial defaults”. 6. After you create a setup, you can use the function key operations described below to start sampling or perform other operations.
  • Page 8 • 2(CH2) ... Channel 2 • 3(CH3) ... Channel 3 • 4(SONIC) ... Sonic channel (2) Selected Sensor (Sensor) • 1(CASIO) ... CASIO sensor • 2(VERN) ... VERNIER sensor • 3(CSTM) ... Custom probe • 4(None) ... No sensor (3) Sample Data Storage Location (Store Data) •...
  • Page 9 Sample Selecting this parameter displays a screen for making real-time settings, and for specifying the sampling interval, number of samples, measurement time recording method, and storage location for measurement time records. • To change Sample Setup settings 1. While the Advanced Setup menu is on the display, press c(Sample). •...
  • Page 10 (4) Measurement Time Recording Method (Rec Time) • 1(None) ... No time recorded. • 2(Abs) ... Absolute time in seconds from start of sampling • 3(Rel) ... Relative time (interval between samples) in seconds • 4(Int A) ... Absolute time calculated from sampling interval and number of samples •...
  • Page 11 2. Use the function key operations described below to change Trigger Setup settings. • To change the setting of an item, first use the f and c cursor keys to move the highlighting to the item. Next, use the function keys to select the setting you want. (1) Trigger Source (Source) •...
  • Page 12 Option Use the Option Setup screen to make View Window settings, to specify the channel for real- time sampling, and to make filter settings. • To change Option Setup settings 1. While the Advanced Setup menu is on the display, press e(Option). •...
  • Page 13 You can use either of the two following procedures to create a new custom probe configuration while creating an EA-100 setup using Advanced Setup. The term “custom probe” means any sensor other than the CASIO or VERNIER sensors specified as standard for the E-CON Mode. 2-11 EA-100 Setup c(9-p): 9-point...
  • Page 14 • To configure a custom probe starting from the Advanced Setup menu 1. From the E-CON main menu, press 1(SETUP) and then c(Advan) to display the Advanced Setup menu. • See “Creating an EA-100 Setup Using Advanced Setup” on page 2-4 for more information.
  • Page 15 • To configure a custom probe starting from the Channel parameter setting screen 1. From the E-CON main menu, press 1(SETUP) and then c(Advan) to display the Advanced Setup menu. • See “Creating an EA-100 Setup Using Advanced Setup” on page 2-4 for more information.
  • Page 16 u To use the MULTIMETER Mode You can use the Channel parameter settings of Advanced Setup to configure a channel so that EA-100 MULTIMETER Mode sampling is triggered by a calculator operation. 1. Use the Channel parameter setting Sensor item to configure a sensor. •...
  • Page 17: Setup Memory

    • While the E-CON main menu is on the display Performing the setup save operation while the E-CON main menu is on the display saves the contents of the current setup memory area (which were created using Setup Wizard or Advanced Setup).
  • Page 18 You can use the following procedure to check the contents of a setup before you use it for sampling. 1. On the E-CON main menu, press 2(MEM) to display the setup memory list. 2. Use the f and c cursor keys to highlight the name of the setup you want.
  • Page 19 • To recall a setup and use it for sampling 1. On the E-CON main menu, press 2(MEM) to display the setup memory list. 2. Use the f and c cursor keys to highlight the name of the setup you want.
  • Page 20 To delete setup data 1. On the E-CON main menu, press 2(MEM) to display the setup memory list. 2. Use the f and c cursor keys to highlight the name of the setup you want. 3. Press 4(DEL). 4. In response to the confirmation message that appears, press w to delete the setup.
  • Page 21: Program Converter

    • While the E-CON main menu is on the display Performing the program converter operation while the E-CON main menu is on the display converts the contents of the current setup memory area (which were created using Setup Wizard or Advanced Setup).
  • Page 22 3. Press w. • This starts conversion of the setup data to a program. • The message “Complete!” appears when conversion is complete. u To convert setup data to a program and transfer it to a CFX-9850 Series/ fx-7400 Series calculator 1.
  • Page 23: Before Getting Started

    5. Starting a Sampling Operation The section describes how to use a setup created using the E-CON Mode to start an EA-100 sampling operation. k Before getting started... Be sure to perform the following steps before starting sampling with the EA-100.
  • Page 24 • If the Advanced Setup menu screen is on the display, press 1(START). • If the E-CON main menu screen is on the display, press 4(START). • This sets up the EA-100 using the setup data in the current setup memory area.
  • Page 25 Starting a Sampling Operation...