Superior DR-400 Installation Instructions Manual page 15

Vented gas fireplace heaters - direct vent models
Table of Contents

Advertisement

If the terminus of the last section is not within
this distance, use the telescopic vent section
SV4.5LA, as the last vent section. For wall
thicknesses greater than that shown in Figure
31 , refer to table 3 on page 16 . This table lists
the additional venting components needed (in
addition to the termination and adapter) for a
particular range of wall thicknesses.
When using long square (SV4.5HTSSL)
horizontal termination -
Assemble the vent system to point where the
terminus of the last section is within 0 in. (0
mm) to 9
in. (248 mm) inboard of the
exterior surface to which the termination is to
be attached, see Figure 32 .
K. When using square (SV4.5HTS) or short
square (SV4.5 HTSS) horizontal termination
- attach termination adapter -
Attach the adapter (adapter - SV4.5RCH - pro-
vided with the termination) to the vent section or
telescoping vent section), elbow or appliance
collar as shown in Figure 29 in the same manner
as any SV4.5 vent component (refer to Step E).
L. Install Firestop/Spacer at exterior wall -
When using either of the square terminations,
install SV4.5HF (Secure Vent), or SF4.5HF
(Secure Flex) firestop/spacer over the opening
at the exterior side of the framing, long side up,
with the 3 inch spacer clearance at the top as
shown in Figure 29 or 30 , and nail into place.
(The Firestop/Spacer may be installed over the
opening at the interior side of the framing.)
When using the round termination, a separate
firestop/spacer is not required since this termi-
nation has integral spacers which provide the
same function as a separate firestop/spacer.
*Note - Firestop/Spacer
(SV4.5HF) required, but
not shown for clarity.
Interior Surface of Finished Wall
Maximum Extent of
Vent Run Sections
Relative to Exterior
Surface of Framing
Last Vent Section. Use
Telescopic Vent Section
(SV4.5LA), If Necessary
Adapter
SV4.5RCH
Siding
SV4.5HTSS Short Square
Termination Shown
Stucco
*Firestop/Spacer (SV4.5HF) shown
on the exterior side of the wall. It
may also be installed on the
interior side.
*Note - Firestop/Spacer integral
with round termination
(SV4.5HTR)
*Note - When using Secure Flex
use Firestop/Spacer SF4.5HF
See Venting Figures for Use
Restrictions on the Horizontal
Round Termination (SV4.5HTR).
6 to 48 inch Vent Section,
Telescopic vent section,
Elbow or Appliance Collar
Figure 29
*Firestop/Spacer (SV4.5HF) shown
on the exterior side of the wall. It
may also be installed on the
interior side.
Note: Centerline of Vent Piping is
NOT the Same as the Centerline of
the Framed Opening.
See Figure 9 on page 7
for Min. Distance to
Base of Appliance.
Base of Appliance
6 to 48 inch Vent Section,
Elbow or Appliance Collar
*When using Secure Flex, use
Firestop/Spacer (SF4.5HF)
Figure 30
Minimum wall thickness
*6 in. (152 mm)
Maximum wall thickness
10
in. (260 mm)
Exterior Surface of Siding
Exterior Surface of Framing
6 in. to 10
in.
(152 mm to 260 mm)
*Cut termination collar
for wall thicknesses
less than 6 in. (152 mm).
SV4.5HTSS Short
Square Termination
Shown
1 " Maximum Recess of Square
Termination into Exterior Finishing
Material. Round Termination may
not be recessed at all.
*When using Secure Flex, use
Firestop/Spacer SF4.5HF
Connecting/Recessing
Square (SV4.5HTS)
Short Square (SV4.5HTSS)
or Round (SV4.5HTR)
Figure 31
Horizontal Termination
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
10 "
(267 mm)
Adapter
SV4.5RCH
Note: Centerline of Vent
Piping is NOT the Same as
the Centerline of the
Framed Opening.
Installing Square HorizontalTermination (SV4.5HTS) Short Square Horizontal
Termination (SV4.5HTSS) Round Horizontal Termination (SV4.5HTR)
10 "
(267 mm)
Installing Long Square HorizontalTermination (SV4.5HTSSL)
*Cut termination collar
for wall thicknesses
less than 10
in. (273 mm).
Interior Surface of
Finished Wall
Maximum Extent of
Vent Run Sections
Relative to Exterior
Surface of Framing
Last Vent Section
Termination Securing
Screw
Siding
Stucco
SV4.5 HTSS
Termination
Shown.
7"
(178)
5 "
(130 mm)
12 "
(308 mm)
See Figure 9 on page
7 for Min. Distance to
Base of Appliance
SV4.5 HTSSL
Termination
(25.4 mm)
7"
(178)
5 "
(130 mm)
12 "
(308 mm)
Minimum wall thickness
*10
Maximum wall thickness
20 in. (508 mm)
Exterior Surface of Siding
Exterior Surface of Framing
10
to 20 in.
(273 to 508 mm)
1 " Maximum Recess of
Square Termination into
Exterior Finishing Material
*Note - Firestop/Spacer
(SV4.5HF) required, but not
shown for clarity.
*When using Secure Flex, use
Firestop/Spacer SF4.5HF.
SV4.5HTSSL Long
Connecting/Recessing
Square Termination
Long Square Horizontal
Figure 32
Termination (SV4.5HTSSL)
3"
(76 mm)
1"
(25.4 mm)
Base of Appliance.
3"
(76 mm)
1"
in. (273 mm)
SV4.5HTSSL Long
Square Termination
15