MAINTENANCE INSTRUCTIONS

(See Maintenance Schedule, Page 26)
Refer to the maintenance schedule for maintenance
tasks, procedures, frequency, and by whom they
should be performed. Always verify proper opera-
tion of the appliance after servicing.
WARNING
Turn off gas and electrical power
to the fireplace and allow it to
cool before cleaning or servicing
the appliance.
CAUTION: Wear gloves and safety
glasses for protection while performing
required maintenance.
Verify proper operation after servicing.
S'assurer que l'appareil fonctionne
adéquatement une fois l'entretien
terminé.
Always turn off gas to the pilot (millivolt
appliances) before cleaning.
Before relighting the fireplace, refer to
the lighting instructions in this manual.
Instructions are also found on pull-out
panels located below the glass enclosure
panel, in the appliance control compart-
ment.
Inspect Venting System
The appliance and venting system should be
thoroughly inspected before initial use and
at least annually by a qualified service techni-
cian (inspection should include ensuring that
exhaust or intake passages are unobstructed
and vent components are properly assembled
and not damaged). Homeowner must contact
a qualified service technician at once if any
abnormal condition is observed.
If the venting system is disassembled for any
reason, a qualified service technician should
follow vent installation instructions for proper
reassembly and proper sealing of the venting
system components. However, more frequent
periodic inspections and cleanings should be
performed by the homeowner.
Inspect Glass Gasket
Visually inspect the gasket on the backside
of the glass enclosure panels. The gasket
surface must be clean, free of irregularities
and seated firmly.
10
SUPERIOR
B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS
®
Clean Glass Enclosure Panel
(Refer to "Removing and Installaing the Glass
Enclosure Panel" on Page 11).
Note: Clean glass after first two weeks of
operation (after burn-in period is over) and
then only when necessary and ONLY WHEN
THE APPLIANCE IS COOL. Wipe surface with
clean, dampened, soft cloth. Follow with dry,
soft towel as desired. Take care not to scratch
the glass surface.
IMPORTANT: Do not use abrasive clean-
ers on glass. Never clean the glass when
it is hot.
Clean the glass periodically, to remove any
buildup caused by the following:
• Filmy coating (during initial use after instal-
lation). Initial curing of the high temperature
paint and burning off of lubricants used in
the manufacturing process may result in a
filmy coating on the glass.
• Dusty or dirty buildup. It is normal for con-
densation and fog to form on the inside of
the glass when first starting the appliance.
This condensation and fog will usually
disappear within a few minutes; however,
over time the moisture can cause lint, dust,
and other airborne particles to cling to the
glass surface.
• White coating. A white coating may form on
the glass as a result of impurities and miner-
als in the fuel.
It is recommended that the glass be cleaned
two or three times during each heating season,
depending on the circumstances. The follow-
ing cleaning solutions are approved for use to
clean the glass:
• Non-ammonia based household cleaner
• 50% white vinegar and 50% water
• Gas fireplace/stove glass cleaner
Clean Control Compartment
Keep control compartment clean by vacuuming
or brushing at least twice a year. More frequent
cleaning may be required due to excessive lint
from carpeting, bedding materials, etc. It is
important that control compartments, burners
and circulating air passageways of the appli-
ance be kept clean.
Clean Logs and Burner
Carefully remove the logs.
Note: Use care when handling the logs, as
they become quite fragile after curing.
Vacuum out any foreign matter (lint, carbon,
etc.) on the burner. Ensure the burner ports are
"open." Remove any carbon deposits from the
under side of the logs using a vacuum cleaner,
or a soft bristled brush (i.e. paint brush).
Note: Improper positioning of logs can
create carbon buildup and will alter the
performance of the appliance.
Order Replacement Logs
If the logs become damaged and need to be
replaced, use only the proper replacement logs
from the manufacturer (see Pages 13 and 14
for ordering information).
Reinstall Embers and Logs
Carefully follow placement instructions on
Pages 12–14. All logs should fit onto corre-
sponding pins and/or log stoppers. This will
ensure a proper flame and safe combustion.
Inspect Wiring
Refer to wiring diagrams on Pages 18 and
19.
CAUTION: Label all wires prior to discon-
nection when servicing controls. Wiring
errors can cause improper and dangerous
operation. Verify proper operation after
servicing.
ATTENTION: Au moment de l'entretien
des commandes, étiquetez tous les fils
avant de les débrancher. Des erreurs de
cáblage peuvent entraîner un fonction-
nement inadéquat et dangereux.
Inspect and clean all wire connections. Ensure
that there is no melting or damage. Inspection
should include:
• Terminals at the Valve
• Optional Control Switch (Wall ON/OFF
Switch, Unit-Mounted ON/OFF Switch, or
Remote ON/OFF Control System)
Inspect Burner Flame Appearance
Ensure that the burner flame appearance
resembles the flame shown in Figures 11 and
12 and as described in "Flame Appearance and
Sooting" on Page q5. The Homeowner must
contact a qualified service technician at once
if any abnormal condition is observed.
Small Area Paint Touch-up
If the surface becomes stained or marred, it
may be lightly sanded and touched-up with
spray paint available from your local authorized
Lennox Hearth Products dealer.
NOTE:
• Only use factory-supplied paint for
touch-ups.
• Never attempt to paint a hot fireplace.