Lenovo ThinkServer TD100 Installation Manual page 40

Types 4203, 4204, 4205, 4206, 6398, 6399, 6419, and 6429
Hide thumbs Also See for ThinkServer TD100:
Table of Contents

Advertisement

10. Raise the power-supply cage slightly and press and hold the release tab on
11. Install the rear fan and fan structure on the chassis:
24
ThinkServer TD100 and TD100x Types 4203, 4204, 4205, 4206, 6398, 6399, 6419, and 6429: Installation Guide
1) Grasp the top of the plastic push pins and pull them out of the rivets
(close-up of pin 5 and rivet 6 ) .
2) Grasp the rivets and pull them out of the mounting holes and set them
to the side.
Note: If the DIMM air duct in your server is secured with screws,
remove the screws.
b. Push the air duct up toward the rear of the power-supply cage. When the
locator pins 4 are free of the power-supply cage, you can remove the air
duct from the server.
c. Position the transition duct 1 so that the two tabs are directly over the
slots on the side of the DIMM air duct 3 .
d. Slide the transition duct into the slots until it clicks into place.
9. Reinstall the DIMM air duct onto the power-supply cage.
the rear power-supply support bracket; then, lower the power-supply structure
into position.
a. Align the clips on the rear fan assembly 1 with the holes in the chassis.
b. Slide the assembly toward the power-supply cage until it stops.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinkserver td100x

Table of Contents