PLC-XL51 Expand Serial Command Functional Specifications
8.10.24 CF_TESTPAT Command
Command
"CF_TESTPAT_%1" [CR]
"COLOR" ---------------------- Display Color bar
"GRAD1" ---------------------- Display 16step(white→black)
"GRAD2" ---------------------- Display 16step(white←black)
"GRAD3" ---------------------- Display 16step(white↓black)
"GRAD4" ---------------------- Display 16step(white↑black)
%1
"WHITE" ---------------------- Display all white
"BALCK" ---------------------- Display all black
"CROSS" --------------------- Display Cross
"OFF" --------------------------Do not show test pattern display
"UP" --------------------------- Switch forward
"DN" ---------------------- Switch backward
Details
Execute test pattern display.(Available only in the normal Power ON status)
Acceptable
Response
Unacceptable
8.10.25 CF_FDEFAULT Command
Command
"CF_FDEFAULT_%1"[CR]
%1
"RST"
Set the value to Factory Default
Details
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000"[CR]
"Error Code"[CR]
36/63