Connecting to the Network
To connect an LC cable connector to a fixed LC connector of a Mini‐GBIC:
1.
Remove the protective covers from the Mini‐GBIC LC fiber‐optic port and from the 
connectors on each end of the cable.
2.
Insert the LC cable connector into the Mini‐GBIC LC connector until it clicks into 
place.
3.
Plug the other end of the cable into the appropriate port on the other device. Some 
cables may be terminated at the other end with two separate connectors, one for each 
fiber‐optic strand. In this case, ensure that the transmit fiber‐optic strand is connected 
to the receive port and the receive fiber‐optic strand to the transmit port.
4.
Verify that a link exists by checking that the port Link/Activity LED is on (blinking 
green or solid green). If the Link/Activity LED is off, perform the following steps until 
it is on:
a.
b. If there are separate fiber‐optic connections on the other device, check the 
c.
d. If a link has not been established, refer to Chapter 4 for LED troubleshooting 
5.
Repeat steps 1 through 4, above, until all connections have been made.
3-28 Hardware Installation
Caution: Do not touch the ends of the fiber-optic strands, and do not let the ends come in
contact with dust, dirt, or other contaminants. Contamination of cable ends causes
problems in data transmissions. If the ends of the fiber-optic strands become
contaminated, use a canned duster to blow the surfaces clean. A fiber-port cleaning swab
saturated with optical-grade isopropyl alcohol may also be used to clean the ends.
Precaución: No toque los extremos de los cables de fibra óptica y evite su contacto con
el polvo, la suciedad o con cualquier otro contaminante. Si los extremos de los cables se
ensucian, es posible que la transmisión de datos se vea afectada. Si nota que los
extremos de los cables de fibra óptica se ensucian, utilice aire comprimido para limpiarlos.
También puede limpiarlos con un estropajo embebido en alcohol isopropílico.
Note: Leave the protective covers in place when the connectors are not in use to prevent
contamination.
Note: To remove the LC cable connector, press on its release tab and pull it out of
Mini-GBIC LC connector.
Verify that the device at the other end of the segment is powered ON and 
connected to the segment.
crossover of the cables. Swap the cable connections if necessary.
Check that the fiber‐optic connection meets the dB loss and cable specifications 
outlined in the Cabling Guide for multimode mode cabling. To obtain this 
document, refer to "Related Documents"  on page xiv. 
details. If a problem persists, refer to refer to "Getting Help" on page 1‐6 for 
details on contacting Enterasys Networks for support.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents