Setting The Ip Address - Enterasys 6E2xx Local Management User’s Manual

Matrix e7 series and smartswitch 6000 series modules
Table of Contents

Advertisement

Chassis Configuration Screen
Table 4-2 Chassis Configuration Screen Field Descriptions (Continued)
Use this field...
Screen Lockout
Time
(Modifiable)
Chassis Uptime
(Read-Only)
4.2.1

Setting the IP Address

To set the IP address, perform the following steps:
1. Use the arrow keys to highlight the IP Address field.
2. Enter the IP address into this field using Decimal Dotted Notation (DDN) format
(nnn.nnn.nnn.nnn).
3. Press ENTER. If the IP address is a valid format, the cursor returns to the beginning of the IP
address field. If the entry is not valid, the Event Message Line displays "INVALID IP
ADDRESS OR FORMAT ENTERED". Local Management does not alter the current value and
refreshes the IP address field with the previous value.
4. Use the arrow keys to highlight the SAVE command, then press ENTER. The "SAVED OK"
message displays indicating that the changes have been saved to memory.
4-6
Chassis Menu Screens
To...
Set the maximum number of minutes that the Local Management
application displays a module's screen while awaiting input or action
from a user. For example, if the number 5 is entered in this field, the
user has up to five minutes to respond to each of the specified module's
Local Management screens. In this example, after five minutes of
"idleness" (no input or action), the terminal "beeps" five times, the
Local Management application terminates the session, and the display
returns to the Password screen. To enter a new lockout time, refer to
Section
4.2.6.
Display the total time the chassis has been operating. The chassis
uptime is based on which interface module installed in the chassis has
been operating for the longest period of time.

Advertisement

Table of Contents
loading

Table of Contents