Table 4-1 LANVIEW LEDs (Continued)
LED
Color
CPU
Off
Red
Amber
Green
Amber
and
Green
RX
Off
(Receive)
Green
Amber
Red
State
Power off.
Blinking. Hardware
failure has occurred.
Solid. Resetting, normal
power up reset.
Blinking. Crippled.
Solid. Testing.
Solid. Functional.
Booting. Blinks amber
and green while booting.
No link.
Solid. Port enabled, link,
no activity.
Blinking. Port disabled,
link.
Flashing. Port enabled,
link, activity.
Diagnostic failure.
Recommended Action
Power up device.
Contact Enterasys Networks for assistance.
If the LED remains red for several minutes,
contact Enterasys Networks for assistance.
Contact Enterasys Networks for assistance.
If the LED remains amber for several
minutes, contact Enterasys Networks for
assistance.
None.
None.
None.
None.
None.
None.
Contact Enterasys Networks for assistance.