Carrier EACAAXCC0014 Installation And Operation Manual page 24

Electronic air cleaner sizes 0014, 0020 & 2020
Table of Contents

Advertisement

ELECTRICAL INSTALLATION
A)I wiring must comply with applicable local and national codes.
I
Be sure
all incoming
power
is OFF
before
beginning any procedures.
I The following instructionsare for use by qualified personnel only.
I _
L
J
The Electronic
Air Cleaner (without the AFS installed at the factory) is designed to take advantage of the integrated
accessory control panel available on most furnaces.
The 12OV Electronic Air Cleaner tap on the furnace will provide
power to the air cleaner only when the circulating air blower is in operation.
Read the instructions in the furnace installation
manual carefully before attempting
instal_efion or operation. Failure to
follow these instructions
may result in improper installation and therefore void warranty.
An optionef(on 120v model) electronic
air l_ow sensor kit is available ifthe air cleaner is not equipped with an AFS. This
air _ow sensor will sense the air movement
w_thin the duct and turn the Electronic/_r
Cleaner on and off accordingly.
Figure
8
• I
[IW:_.lllllt|]
_
WIRING
PROCEDURE
This air cleaner
is powered by providing
power to pigtail
leads at field wiring
compartment
(see knoCk-Out holes)
loCated at the rear of the power pack assembly
(See Fig.
0).
1. Turn air cleaner
OFF using ON/OFF switch located on
front panel.
2. Remove
power
pack cover plate by removing front
door and two screws holding assembly
to the top of
theair cleaner.
3. Make wiring connections
inside junction
box area
(See Fig. 8). Remove knOCk-Out and use conduit
or
other
approved
methods
to supply
input
power.
Connect g round wire to clip.
4. Replace the power supply cover plate and secure with
screws removed
from step 2.
5. Replacethe
unit door to the front of the air cleaner.
6, Air cleaner will now operate when door is Ln place,
ON/OFF rocker switch is in the ON position and input
voltage is present
in the junction box. The following
should be oompIcted to supply input power to the _r
cleaner.
FURNACE
APPLICATION
It is recommended
to use EAC t and EAC 2 terminals
when
provided
by the furnace
circuit
hoard.
These
outputs will provide
120 vac whenever the blower motor
is energized.
Furnace
circuit boards
without EAC
1 and EAC
2
terminals
MUST
use alternate
methods
to supply
to
supply power
to the air cleaner. Options
include Sail
Switch, Isolation relay or Optional AFS (Air F!ow Sensor)
Air cleaner should
only operate when blower
motor is
running.
This unit cannot be powered directly from blower motor
/
leads. Voltages can exceed t 90vac for 120-v. motors or
possibly double with 240-v fan coil motors,
j
FAN COIL APPLICATION of 0014 or 0020 Models (120-v.)
if EAC I and F_AC2 terminals are provided by fan coil
circuit board, refer to fan coil data to determine
voltage
output.
Most fan coils do not provide
120-v. at these
termina!s.
Alternate methods may be needed to eonved
fan coil supply voltage to 120-v. for the cleaner. A 240-v. to
120-v step down transformer (60 v) will be needed in most
applications.
Sail Switch, Isolation relay or Optional AFS
(Air Flow Sensor) may also be needed,
FAN COIL APPLICATION
of 2020 Model (240-v.)
The Model 2020 is a 240-v, power supply model designed
to match you fan coil, To install this model with a g40-v, far_
coil:
_|_:tl|
I[IU
I
This unit cannot he powered directly from blower motor
leads. Back EMF (electro magnetic field) voltages
can
l
reach40Ovao
or240-v.fanco
mo ors.
J
1. "rum air cleaner OFF using ON/OFF
rocker switch
loCated on front panel
2, Remove power
pack cover plate by removing
front
door and two screws holding assembly to the top of the
aircteanec
3. Make wiring connections inside )unction box area (See
Fig 8). Remove knock-out and use conduit
or other
approved
methods
to supply input powe_
Connect
ground wireto clip,
4. Rep(ace the power supply cover plate and secure with
screws removed from step 2.
5. Replace the unit door to the front of _he air cleaner.
6. Air cleaner will now operate
when
door
in place,
ON/OFF
rocker switch is in the ON position
and input
voltage is present in the junction box.
22