Washing The Cells And Prefilter (S); Replacing The Cells And Prefilter(S) - Carrier EACAAXCC0014 Installation And Operation Manual

Electronic air cleaner sizes 0014, 0020 & 2020
Table of Contents

Advertisement

Towash cells and
prefilter(s)
We suggest
that you follow the instructions
below to properly
and
thoroughly
clean your collector
cells.
1. Place enough
hot water in a utility tub to cover the first cell. Dissolve
2
to 4 oz. of granulated
automatic
dishwasher
detergent
(not laundry
detergent)
in the water.
2. Allow the cell to soak for 30 minutes.
Agitate
it up and down
in the
solution
until it appears
clean and remove.
3. Repeat with second
cell.
4. Agitate
the prefilters
up and down
in the solution
until they appear
clean.
5. With a hose, rinse the cells and prefilters.
The hose should
be held
about
10" from the cell plates and at a slight angle for better cleaning
results.
Be careful not to spray the ionizing
wires directly
with the
hose. The water pressure
can cause the wire to snap and break. The
cell frame should be thoroughly
rinsed
along the edges
to dislodge
any trapped
lint or dirt. Carefully
wipe a damp
cloth or sandpaper
(not
emery cloth) along the ionizing
wires.
6. Stand cells and prefilters
up to drain.
Let dry two hours. You may
experience
a slight discoloration
of the aluminum
collector
cells after
washing.
This is a normal
chemical
reaction
and will not harm your
unit or affect its performance.
To replace
cells in air cleaner
1. Replace
prefilter and cells in cabinet.
Check that arrow on cells points
in same direction
as air flows through
the duct.
(If you have to force it
past the positioning
screw on bottom,
it is probably
in the wrong
position.)
2. Replace
access door (engage tabs on lower edge of door into slots in
cabinet).
Carefully
close door.
3. Turn air cleaner switch to ON.