TABLE OF CONTENTS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

Congratulations for selecting the Infinityt Air Purifier for your
home comfort system! The Infinityt Air Purifier is proven to
remove and kill airborne germs and allergens, including viruses,
bacteria, and mold spores. The Infinity t Air Purifier is a
cornerstone of Carrier's Healthy Home Solutions for providing
healthier, cleaner air in your home.

HOW IT WORKS

The Infinityt Air Purifier provides extremely high filtration
performance while killing captured contaminants, including
viruses, bacteria, and mold spores. The Infinityt Air Purifier
treats the entire air- -stream through a state of the art, three- -stage
process, exclusive to Carrier.
In stage one, the particles are electrically charged by a
precision- -point ionization array as they enter the Infinityt Air
Purifier.
In stage two, the charged particles are electrically attracted to
the air purification cartridge, which is located within an electric
field.
In stage three, captured particles are killed by electrical current
flow and ion bombardment.
Operating Instructions
Page
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
3- -5
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
1
1
1
2
6
6
7
8
9

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service,
maintenance, or use can cause explosion, fire, electrical shock
or other conditions which may cause personal injury or property
damage. Consult a qualified installer, service agency, or your
distributor or branch for information or assistance. The
qualified installer or agency must use factory authorized kits or
accessories when modifying this product. Refer to the
individual instructions packaged with the kits or accessories
when installing.
Follow all safety codes. Wear safety glasses and work gloves.
Have fire extinguisher available. Read these instructions
thoroughly and follow all warning or cautions attached to the
unit. Consult local building codes and National Electrical Code
(NEC) for special requirements.
It is important to recognize safety information. This is the
safety- -alert symbol
and in instructions or manuals, be alert to the potential for
personal injury. Understand the signal words DANGER,
WARNING, and CAUTION. These words are used with the
safety- -alert symbol. DANGER identifies the most serious
hazards which will result in severe personal injury or death.
WARNING signifies hazards which could result in personal
injury or death. CAUTION is used to identify unsafe practices
which may result in personal injury or product and property
damage. NOTE is used to highlight suggestions which will
result in enhanced installation, reliability, or operation.
1
Fig. 1 - - GAPA Unit
. When you see this symbol on the unit
A05265

Advertisement

Table of Contents
loading

Summary of Contents for Carrier INFINITY 1625

  • Page 1: Table Of Contents

    The Infinityt Air Purifier is proven to remove and kill airborne germs and allergens, including viruses, bacteria, and mold spores. The Infinity t Air Purifier is a cornerstone of Carrier’s Healthy Home Solutions for providing healthier, cleaner air in your home. HOW IT WORKS...
  • Page 2: Application Considerations

    If EAC terminals are not available, an alternative airflow sensing mechanism must be used to ensure the Infinityt Air Purifier is only powered when airflow is present. Contact local Carrier distributor for information on approved alternatives. Air Purification Cartridge (x1)
  • Page 3: Installation

    INSTALLATION Step 6—Check Infinityt Air Purifier Components CAUTION CUT HAZARD Failure to follow this caution may result in personal injury. Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing and gloves when handling parts. b.
  • Page 4 Step 8—Mount the Cabinet WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death. Before installing or servicing system, always turn off main power to system. There may be more than 1 disconnect switch. CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment...
  • Page 5 If EAC connections are not available, an alternative airflow sensing mechanism must be used to ensure the Infinityt Air Purifier is only powered when airflow is present. Contact a local Carrier distributor for information on approved alternatives. UNIT COMPONENT DAMAGE HAZARD...
  • Page 6: Start- -Up And Operation

    Power Cord to EAC Terminals Use cable connector to secure power cord to cabinet Power Supply Connector Use wire ties to secure power cord to power supply enclosure Alternate Power Cord Pass-Thru Hole Fig. 7 - - Infinityt Air Purifier Electrical Connections START- -UP AND OPERATION Step 1—Checking Air Purifier Operation WARNING...
  • Page 7: Troubleshooting

    Step 2—Turn the Infinityt Air Purifier switch to the off position. Step 3—Remove the Infinityt Air Purifier door. Step 4—Slide out the old air purifier cartridge and discard. Step 5—Install the new air purifier cartridge. NOTE: Make sure that the arrows on the air purifier cartridge point toward the furnace.
  • Page 8: Specifications And Dimensions

    Specifications Color Cabinet Material Electrical Maximum Airflow (CFM) Efficiency Replacement Cartridge Dimensions 1 15/16˝ Table 2—Specifications and Dimensions GAPAAXCC1625 Taupe Metallic 20 Ga. Powder Coated Steel 115v/60 Hz (from furnace EAC terminals) 1600 Equivalent to MERV 15 GAPCCCAR1625 GAPAAXCC1625 18---3/8 15---1/8 11---1/8 17---1/2...
  • Page 9: Warranty

    LIMITED WARRANTY FIVE-YEAR LIMITED WARRANTY – Carrier Corporation (hereinafter referred to as “Company”) warrants this product to be free from defects in material and workmanship. If a defect is found within five years from date of original installation of product (whether or not actual use begins on that date) Company will provide a new or remanufactured part, at Company’s sole option, to replace any defective part, without charge for the part itself.
  • Page 10 Printed in China Edition Date: 3/06 Catalog No: GAPA--- 2SI Copyright 2005 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Replaces: GAPA---1SI...