PLC-WTC500L Basic Serial Command Functional Specifications
7
Status Read Command
7.1 Format
0û
PC issues a command in the following format.
"CR" Command [CR]
Command: one character (See Status Read Command Table)
0û
When projector receives an appropriate command, it returns the required data in string.
Required Data [CR]
Required Data: string (See Status Read Command Table)
0û
When the received data cannot be decoded, the projector returns "?" [CR] is returned.
7.2 Transfer Example
Getting Input mode information of projector by basic commands.
PC ! '
Projector
Projector ! '
7.3 Operation Requirements
When Standby mode of Setting menu is set to Eco and Projector status is Standby mode, Functional
execution commands become invalid
7.4 Status Read Command
Command
"CR0" [CR]
Detail
Get the projector's operating status
Acceptable
Response
Unacceptable
Command (issue current input mode command)
"C" "R"
PC
"%1" [CR]
"00" = Power ON
"80" = Standby
"40" = Countdown in process
"20" = Cooling Down in process
"10" = Power Failure
"28" = Cooling Down in process due to Abnormal Temperature
"88" = Standby after Cooling Down due to Abnormal Temperature
%1
"24" = Power-Save Cooling Down in process
"04" = Power Save
"21" = Cooling Down in process after OFF due to Lamp Failure
"81" = Standby after Cooling Down due to Lamp Failure
"2C" = Cooling Down in process after Power Off due to
Shutter management
"8C" = Standby after Cooling Down due to
Shutter management
"?" [CR]
20/25
"1" CR
! • ! '
Response
(A few
)
ms ÿ ^
5 s
(Indicating Computer 1 is selected)
"1"