On Start Set Command; On Start Cancel Command; Power Management Ready Command; Power Management Cancel Command - Sanyo PLC-WTC500AL - 5000 Lumens Manual

Rs232c basic basic serial command functional specifications
Hide thumbs Also See for PLC-WTC500AL - 5000 Lumens:
Table of Contents

Advertisement

PLC-WTC500L Basic Serial Command Functional Specifications

6.29 ON START SET Command

Command
"C28" [CR]
Enable Power ON Start
Detail
This status is stored in EEPROM and retained regardless of Power OFF/ON
operation.
Acceptable
Response
Unacceptable

6.30 ON START CANCEL Command

Command
"C29" [CR]
Disable Power ON Start
Detail
This status is stored in EEPROM and retained regardless of Power OFF/ON
operation.
Acceptable
Response
Unacceptable

6.31 POWER MANAGEMENT READY Command

Command
"C2A" [CR]
Set Power Management function to ready status
Detail
This status is stored in EEPROM and retained regardless of Power OFF/ON
operation.
Acceptable
Response
Unacceptable

6.32 POWER MANAGEMENT CANCEL Command

Command
"C2B" [CR]
Set Power Management function to off status
Detail
This status is stored in EEPROM and retained regardless of Power OFF/ON
operation.
Acceptable
Response
Unacceptable

6.33 POWER MANAGEMENT SHUTDOWN Command

Command
"C2E" [CR]
Set Power Management function to Shutdown mode.
Detail
This status is stored in EEPROM and retained regardless of Power OFF/ON
operation.
Acceptable
Response
Unacceptable

6.34 D.ZOOM + Command

Command
"C30" [CR]
Enter Digital Zoom mode and expand image size
Detail
This command works the same way as "D.ZOOM " button of the remote control.
Acceptable
Response
Unacceptable
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
14/25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-wtc500l - 5000 lumensPlc-wtc500l

Table of Contents