SNMP
ReadyNAS devices can be set to work with SNMP management systems, such as HP
OpenView or CA UniCenter, to monitor devices on your network.
To set up SNMP service:
1.
Select the SNMP screen to display the SNMP settings.
2.
Select the Enable SNMP service check box. You can leave the Community field set to
public, or specify a private name if you have a more segregated monitoring scheme.
3.
Enter a hostname or an IP address in the Trap destination field. This is where all trap
messages will be sent. The following system events generate a trap:
•
Abnormal power voltage
•
Abnormal board enclosure temperature
•
Fan failure
•
UPS connected
•
UPS detected power failure
•
RAID disk sync started and finished
•
RAID disk added, removed, and failure
•
Snapshot invalidated
4.
If you want to limit SNMP access to only a secure list of hosts, specify the hosts in the Hosts
allowed access field.
5.
Click Apply to save your settings.
When you have saved the SNMP settings on the ReadyNAS, you can import the
NETGEAR SNMP MIB to your SNMP client application. The NETGEAR MIB can be
obtained from the installation CD included with your unit, or downloaded from
http://readynas.com/download.
ReadyNAS for Business RAIDiator 4.2.17
Managing Your ReadyNAS System
40