Important Safety Information; Vent Kit Information - Empire Heating Systems DV-25T-1 Installation Instructions And Owner's Manual

Direct vent wall furnace
Table of Contents

Advertisement

DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED.
• Due to high temperatures the appliance should be located
out of traffic and away from furniture and draperies.
• Children and adults should be alerted to the hazards of
high surface temperatures and should stay away to avoid
burns or clothing ignition.
• Young children should be carefully supervised when they
are in the same room as the appliance.
• Clothing or other flammable material should not be placed
on or near the appliance.
• Any safety screen or guard removed for servicing an
appliance must be replaced prior to operating the ap-
pliance.
• Keep burner and control compartment clean.
• Vent cap hot while furnace is in operation.
• Installation and repair should be done by a QUALIFIED
SERVICE PERSON. The appliance should be inspected
before use and at least annually by a qualified service
person. More frequent cleaning may be required due to
Attention: The DV-25T and DV-35T direct vent wall furnaces are provided with vent kit, DV4T-59-1 for wall depths of
5" to 9". For wall depths greater than 9", refer to Accessories, Page 6. Listed below are the vent kits.
Attention: The minimum wall depth for installation of a DV-25T or DV35T MUST BE 5". If the wall depth is less than
5" you can order DV-822, refer to Accessories, Page 6 or refer to Figure 7 and Figure 8 with accompanying text, Page
10.
13117-9-0907

IMPORTANT SAFETY INFORMATION

THIS IS A HEATING APPLIANCE

VENT KIT INFORMATION

excessive lint from carpeting, bedding materials, etc. It
is imperative that control compartments, burners and
circulating air passageways of the appliance be kept
clean.
• DO NOT put anything around the furnace that will ob-
struct the flow of combustion and ventilation air.
• DO keep the appliance area clear and free from combus-
tible material, gasoline and other flammable vapors and
liquids.
• DO examine venting system periodically and replace
damaged parts.
• DO make a periodic visual check of pilot and burner.
Clean and replace damaged parts.
• CAUTION: Pilot hole cover must be kept tightly closed
during operation.
• DO NOT use this heater if any part has been under water.
Immediately call a qualified service technician to inspect
the heater and to replace any part of the control system
and any gas control which has been under water.
Vents Kits
No.
Part
DV4T-59-1
1
Outlet Tube - Inner
2
Gasket - Outer Collar
3
Outlet Tube - Inner
4
Inlet Tube - Inner
5
Gasket - Inlet Collar
6
Inlet Tube - Inner
7
Inlet Tube - Outer
8
Outlet Tube - Outer
9
Vent Cap
Hardware Kit
DV4T-812-1
DV4T-1219-1
13057
13057
13058
M-177
M-177
M-177
13104
13104
13105
13062
13062
13063
M-178
M-178
M-178
13106
13106
13107
13064
13065
13066
13059
13060
13061
13053
13053
13053
13078
13078
13078
Page 3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dv-35t-1

Table of Contents