Thermostat Location - Empire Heating Systems DV-25T-1 Installation Instructions And Owner's Manual

Direct vent wall furnace
Table of Contents

Advertisement

Millivolt wall thermostats are specially designed for use on self-generating systems. They should never be used on line or low voltage
A.C. circuits.
Interior Wall - The thermostat can also be installed on an inside wall
away from the furnace but in the same room.
It is important to use wire of a gauge proper for the length of the wire:
RECOMMENDED WIRE GAUGES
Maximum Length
1' to 10'
10' to 25'
25' to 35'
Proper operation depends on a good pilot flame. The flame must cover
the top of the thermopile. Cleaning of the pilot orifice and burner may
be required due to spiders.
System Check (Figure 10)
A millivolt meter is required to check the system. Millivolt readings
should be:
• Across
the
thermopile
thermostat OFF.
• Across the thermopile terminals, 150 - 250 millivolts with thermostat
ON
• Across
the
thermostat
wires
millivolts with thermostat ON.
• Across the thermostat wires at the thermostat, less than 5
millivolts with thermostat ON. (Strong winds, dirty pilot and low pres-
sure will reduce readings.)
Piezo Pilot Ignitor Instructions
Depressing the button completely causes a spark to occur at the pilot.
This is a substitute for a match which requires opening the pilot hole
cover.
13117-9-0907

THERMOSTAT LOCATION

Wire Gauge
18
16
14
terminals,
400-450
millivolts
at
the
valve,
less
Figure 9
To light the pilot, it is important that the electrode be 1/8" (3mm) from
the thermopile. The spark must occur at the point the burner flame hits
the thermopile. The end of the electrode will be red hot with the pilot
on.
On a new installation with air in the gas line, it is suggested that a match
be used. The match will light the pilot faster than the piezo under this
condition.
with
than
30
Figure 10
Page 11