SJ300 Inverter Specifications
Tables for 400V class inverters, continued...
Item
SJ300 inverters,
UL version
400V models
CE version
Applicable motor size *2
Rated capacity (400 / 480V) kVA
Rated input voltage
Rated input current (A)
Rated output voltage *3
Rated output current (A)
Efficiency at 100% rated output, %
Watt loss,
at 70% output
approximate (W)
at 100% output
Starting torque *6
Dynamic braking
w/o braking unit
approx. % torque,
with braking unit
short time stop *7
DC braking
Weight
kg / lb
Footnotes for the preceding tables and the table that follows:
Note 1: The protection method conforms to JEM 1030.
Note 2: The applicable motor refers to Hitachi standard 3-phase motor (4-pole). When using
Note 3: The output voltage decreases as the main supply voltage decreases (except when
Note 4: To operate the motor beyond 50/60 Hz, consult the motor manufacturer for the
Note 5: When SLV is selected, please set the carrier frequency higher than 2.1 kHz.
Note 6: At the rated voltage when using a Hitachi standard 3-phase, 4-pole motor (when
Note 7: The braking torque via capacitive feedback is the average deceleration torque at the
Note 8: The frequency command will equal the maximum frequency at 9.8V for input voltage
Note 9: The storage temperature refers to the short-term temperature during transport.
Note 10: Conforms to the test method specified in JIS C0911 (1984). For the model types
Note 11: NEMA 1 applies up to 22kW. An optional wire-entry conduit box is required for
750HFU
900HFU
750HFE
900HFE
HP
100
125
kW
75
90
103.2 / 123.8
121.9 / 146.3
3-phase (3-wire) 380 to 480V ±10%, 50/60 Hz ±5%
164
194
3-phase (3-wire): 380 to 480V (corresponding to input voltage)
149
176
95.2
95.2
2675
3375
3800
4800
180% at 0.5 Hz (SLV), 130% at around 0 Hz (SLV, 0 Hz domain,
with motor one frame size down), 100% at 0 Hz (with feedback board)
45–70%
40–60%
Variable operating frequency, time, and braking force
60 / 132
60 / 132
other motors, care must be taken to prevent the rated motor current (50/60 Hz) from
exceeding the rated output current of the inverter.
using the AVR function). In any case, the output voltage cannot exceed the input
power supply voltage.
maximum allowable rotation speed.
selecting sensorless vector control—SLV).
shortest deceleration (stopping from 50/60 Hz as indicated). It is not continuous
regenerative braking torque. The average decel torque varies with motor loss. This
value decreases when operating beyond 50 Hz. If a large regenerative torque is
required, the optional regenerative braking resistor should be used.
0 to 10 VDC, or at 19.6 mA for input current 4 to 20 mA. If this characteristic is not
satisfactory for your application, contact your Hitachi sales representative.
excluded in the standard specifications, contact your Hitachi sales representative.
30kW to 55kW models to meet NEMA 1 rating.
400V Class Specifications
1100HFU
1100HFE
1320HFE
150
175
110
132
150.3 / 180.4
180.1 / 216.1
239
286
217
260
95.2
95.2
3900
4670
5550
6650
10%
30–50%
25–40%
80 / 176
80 / 176
1500HFU
200
150
180.1 / 216.1
286
260
95.2
4670
6650
20–35%
80 / 176