Tables for 400V
Note that "General Specifications" on page 1–9 covers all SJ300 inverters, followed by
class inverters
footnotes for all specifications tables. The 400V models in the upper table below (1 to 15 hp)
include internal dynamic braking units (see "Dynamic Braking" on page 5–6).
Item
SJ300 inverters,
UL version
400V models
CE version
Applicable motor size *2
Rated capacity (400 / 480V) kVA
Rated input voltage
Rated input current (A)
Rated output voltage *3
Rated output current (A)
Efficiency at 100% rated output, %
Watt loss,
at 70% output
approximate (W)
at 100% output
Starting torque *6
Dynamic braking
internal res. only
approx. % torque,
with external res.
short time stop *7
DC braking
Weight
kg / lb
Item
SJ300 inverters,
UL version
400V models
CE version
Applicable motor size *2
Rated capacity (400 / 480V) kVA
Rated input voltage
Rated input current (A)
Rated output voltage *3
Rated output current (A)
Efficiency at 100% rated output, %
Watt loss,
at 70% output
approximate (W)
at 100% output
Starting torque *6
Dynamic braking
w/o braking unit
approx. % torque,
with braking unit
short time stop *7
DC braking
Weight
kg / lb
007HFU
015HFU
007HFE
015HFE
HP
1
2
kW
0.75
1.5
1.7 / 2.0
2.6 / 3.1
3-phase (3-wire) 380 to 480V ±10%, 50/60 Hz ±5%
2.8
4.2
3-phase (3-wire): 380 to 480V (corresponding to input voltage)
2.5
3.8
89.5
92.3
76
102
88
125
200% at 0.5 Hz (SLV), 150% at around 0 Hz (SLV, 0 Hz domain,
with motor one frame size down), 100% at 0 Hz (with feedback board)
50%
200%
Variable operating frequency, time, and braking force
3.5 / 7.7
3.5 / 7.7
150HFU
185HFU
150HFE
185HFE
HP
20
25
kW
15
18.5
22.1 / 26.6 26.3 / 31.5 33.2 / 39.9 40.1 / 48.2 51.9 / 62.3 62.3 / 74.8
3-phase (3-wire) 380 to 480V ±10%, 50/60 Hz ±5%
35
42
3-phase (3-wire): 380 to 480V (corresponding to input voltage)
32
38
94.9
95.0
575
698
800
975
200% at 0.5 Hz (SLV), 150% at around 0 Hz (SLV, 0 Hz domain,
with motor one frame size down), 100% at 0 Hz (with feedback board)
40–200%
40–200%
Variable operating frequency, time, and braking force
12 / 26.4
12 / 26.4
400V Class Specifications
022HFU
040HFU
055HFU
022HFE
040HFE
055HFE
3
5
7.5
2.2
4.0
5.5
3.6 / 4.4
5.9 / 7.1
8.3 / 9.9
5.8
9.5
13
5.3
8.6
12
93.2
94.0
94.4
127
179
242
160
235
325
20%
140%
3.5 / 7.7
3.5 / 7.7
3.5 / 7.7
400V Class Specifications
220HFU
300HFU
370HFU
220HFE
300HFE
370HFE
30
40
50
22
30
37
53
64
83
48
58
75
95.0
95.1
95.1
820
1100
1345
1150
1550
1900
10%
35–200%
110–170%
90–150%
12 / 26.4
20 / 44
30 / 66
SJ300 Inverter
075HFU
110HFU
075HFE
110HFE
10
15
7.5
11
11 / 13.3
15.9/19.1
18
25
16
23
94.6
94.8
312
435
425
600
10%
100%
70%
55 / 121
55 / 121
450HFU
550HFU
450HFE
550HFE
60
75
45
55
76.2/91.4
99
121
90
110
95.1
95.1
1625
1975
2300
2800
70–120%
60–100%
30 / 66
50 / 110